Environmental Parameters
Parameter
Temperature
Maximum altitude
Relative humidity
Shock
Vibration

AC Power Requirements

Parameter
Nominal Input Voltage
Maximum AC Power
Supply Input Current
Maximum System
Power Input

DC Power Requirements

Parameter
Nominal Input Voltage
Maximum Power
Supply Input Current
Maximum System
Power Input

Power Supplies

The S55 and the S60 are designed to support two hot-swappable power supplies
with integrated fans that provide the cooling for the chassis.
S55 Specifications
32° to 104°F (0° to 40°C)
-40° to 158°F (-40° to 70°C)
No performance degradation
to 10,000 feet (3,048 meters)
10 to 85% non-condensing
MIL-STD-810
S55 Specifications
100 to 240 VAC, 47-63 Hz
5 A
135 W
S55 Specifications
-43 to -72 VDC at startup
-36 to -72 VDC during normal
operation
10 A
135 W
S60 Specifications
32° to 122°F (0° to 50°C)
-40° to 158°F (-40° to 70°C)
non-operating
No performance degradation
to 10,000 feet (3,048 meters)
10 to 85% non-condensing
5 to 95% non-condensing
(non-operating)
MIL-STD-810
Bellcore GR-63
S60 Specifications
100 to 240 VAC, 50/60 Hz
2 A at 100/120 VAC
225W
S60 Specifications
–40 to – 60 VDC
3.6 A at -48 VDC
225W