Fans; Components - Dell Networking S6000 Installation Manual

Fully featured switch/router one rack unit (ru) system
Hide thumbs Also See for Networking S6000:
Table of Contents

Advertisement

Fans

The S6000 comes from the factory with two PSUs and three fan modules installed in the chassis (see
Figure
6-1). The S6000 has SKUs that support the following configurations. Installation of the fans is
done as part of the factory install based on SKU type.
• AC PSU with fan airflow from I/O to PSU
• AC PSU with fan airflow from PSU to I/O
• DC PSU with fan airflow from I/O to PSU
• DC PSU with fan airflow from PSU to I/O
All fans and PSUs in a configuration must be in the same airflow direction. Should a mixed airflow
configuration happen, the software notifies you of the invalid configuration.
The S6000 supports three fan trays with airflow directions from the I/O to the utility or the utility to the
I/O.
Environmental factors can decrease the amount of time required between fan replacements. Check the
environmental factors regularly. An increase in temperature and/or particulate matter in the air might
affect performance (for example, new equipment installation).
CAUTION: Check the fans at six-month intervals and replace them as necessary. Regularly monitor the
speeds of the cooling fans in order to accurately determine replacement intervals.

Components

• S6000 Fan module
• S6000 Fan module - Reverse flow
Figure 6-1. S6000 Fan Modules and PSU