PROVISION FOR VENTILATION

The appliance should be installed into a room or space with an air supply in accordan-
ce with BS 5440-2: 2000 .
For rooms with a volume of less than 5m
will be required .
For rooms with a volume of between 5 m
free area will be required unless the room has a door which opens directly to the outside
air in which case no permanent ventilation is required .
For rooms with a volume greater than 10 m
Note: Regardless of room size, all rooms containing the appliance must have direct
access to the outside air via an openable window or equivalent.
Where there are other fuel burning appliances in the same room, BS 5440-2: 2000
should be consulted to determine the correct amount of free area ventilation require-
ments .
The above requirements allow also for use of a gas oven and grill but if there are other
gas burning appliances in the same room, consult a qualified engineer.

10 - GAS INSTALLATION

IMPORTANT NOTE
This appliance is supplied for use on NATURAL GAS or LPG (check the gas regulation
label attached on the appliance) .
Appliances supplied for use on NATURAL GAS are adjusted for this gas only and
cannot be used on any other gas (LPG) without modification. The appliances are
manufactured for conversion to LPG .
Appliances supplied for use on LPG are adjusted for this gas only and cannot be
used on any other gas (NATURAL GAS) without modification. The appliances are
manufactured for conversion to NATURAL GAS .
If the NATURAL GAS/LPG conversion kit is not supplied with the appliance this kit can be
purchased by contacting the After-Sales Service .
INSTALLATION & SERVICE REGULATIONS (UNITED KINGDOM)
It is a legal requirement that all gas appliances are Installed & Serviced by a competent
person in accordance with the current editions of the following Standards & Regulations or
those regulations appropriate to the geographical region in which they are to be installed:
Gas Safety (Installation & Use) Regulations
Building Regulations
British/European Standards
Regulations for Electrical Installation
30
- permanent ventilation of 100 cm
3
and 10 m
a permanent ventilation of 50 cm
3
3
- no permanent ventilation is required .
3
free area
2
2