S
CANNING
The VX-3R/E allows you to scan just the memory channels, the entire operating band, or a
portion of that band. It will halt on signals encountered, so you can talk to the station(s) on
that frequency, if you like.
Scanning operation is basically the same in each of the above modes. Before you begin,
take a moment to select the way in which you would like the scanner to resume scanning
after it halts on a signal.
S
S
ETTING THE
CAN
Eleven options for the Scan-Resume mode are available:
2 SEC - 10 SEC: In this mode, the scanner will halt on a signal it encounters, and will hold
there for the selected resume time. If you do not take action to disable
the scanner within that time period, the scanner will resume even if the
stations are still active.
BUSY:
In this mode, the scanner will halt on a signal it encounters. When the
carrier has dropped because the other station(s) ceased transmission, the
scanner will resume. In the case of constant-carrier signals like Weather
Station broadcasts, the scanner will likely remain on this frequency in-
definitely. The Scan Re-start Delay time (default interval: 2 seconds) is
set by the Set Mode Item 76: SCN.STR.
In this mode, the scanner will halt on a signal it encounters. It will not
HOLD:
restart automatically; you must manually re-initiate scanning if you wish
to resume.
To set the Scan-Resume mode:
1. Press and hold in the [ TXPO ] key for one second to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 75: SCN.RSM.
Note: Do not forget to pull the DIAL knob to rotate the DIAL
knob.
3. Press the [ TXPO ] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to select the desired scan-resume mode
described above.
5. When you have made your selection, press the PTT switch to save the new setting and
exit to normal operation.
The default condition for this Set Mode Item is "5 SEC."