Wiring The Fan Coil Unit For Power - Wine Guardian SS025 Installation, Operation And Maintenance Manual

Ducted split wine cellar cooling systems
Table of Contents

Advertisement

Wiring the Fan Coil Unit for Power

The electrical outlet and wiring installation must meet the national and local
DO:
 Match the electrical wiring to the cord provided on the Wine Guardian. 
 Provide dedicated circuit and wiring for the system.
 Match the wiring and breaker size to the rated load as shown on the serial
plate and in this guide. See sample serial plate illustration below.
Electrical
Evaporator Fan Amps
Total Unit Amps (w/o opt.)
Min. Circuit Amps (w/o opt.)
Air Innovations, 7000 Performance Drive, North Syracuse, New York 13212
Ph:800-535-3295 * 315-452-7400 * Fax: 315-452-7420
.
DO NOT:
 DO NOT MODIFY THE PLUGS IN ANY WAY! 
 Do not use extension cords.
The electrical power supply must be either 115 volt or 230 volt AC 1 phase 60 cycle, depending
on the model of the unit, and cannot vary more than plus or minus 4% or damage may occur
Plug the unit into the wall outlet. Gently pull on the plug to make sure it is tight.



Neutral
ELECTRICAL SHOCK HAZARD
RISK OF SERIOUS INJURY OR DEATH
building codes.
Model# SS088
230/1/60
0.8
0.8
1
IMPORTANT
to the unit.
DANGER
Serial# 11L18342
Electric Heat Amps
(opt.)
Humidifier Amps (opt.)
Crankcase Htr. Amps.
Refrigerant
Test Pressure
6.7
0.3
0.2
R-134-A
275psi
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ss050Ss088Ss20015h0128-00Wgs40Wgs75 ... Show all

Table of Contents