Rotating Fan Blades are present in the Wine Guardian unit. Sticking a hand into an exposed fan
while under power could result in serious injury. Be sure to use the Lockout/Tagout procedure
when working in this area or remove the power cord.

Equipment Safety Interlocks

There are no electrical safety lockouts installed within the unit. The power cord attached to the
control box must be disconnected from the power sources prior to working on any part of the
electrical system.

Main Power Switch

The main power switch is located on the side of the Wine Guardian unit. (See Fig.1 on page 36)
It shuts off the power to the fan coil unit. A separate disconnect switch will be wired to the
condensing unit. Both switches must be turned off prior to servicing equipment.
Energy Type
Hazard ....................................Electrocution, electrical burns and shock
Magnitude ..............................120 VAC and 230 VAC, 1phase, 60 hertz cycles
Control Method ......................Disconnect power cord and On/Off switch
 Never
reach into a unit while the fan is running.
 Never
open an access door to a fan while the fan is running.
 Disconnect
than one power source to disconnect.
 Avoid
risk of fire or electric shock.
 Check
weights to be sure that the rigging equipment can support and move the Wine
Guardian unit safely. Note any specific rigging and installation instructions located in the
Installation section of this manual.
All supports for the unit
any additional live or dead loads encountered.
All supports for the unit
ordinances.
 Do not
remove access panels until fan impellers have completely stopped. Pressure
developed by moving impellers can cause excessive force against the access
panels.
Fan impellers continue to turn (free-wheel) after the power is shut off.
20
Electrical
DANGER
the power cord switch before working on the unit. The unit may have more
WARNING
be capable of safely supporting the equipment's weight and
must
must
be designed to meet applicable local codes and
Do not
expose the unit to
rain
or
moisture.