Humidity too low, without optional humidifier
Possible Cause
No moisture being added to cellar
Humidity too low, with optional humidifier
Possible Cause
Humidifier not operating
Humidifier operating
Humidity too high when unit is running but not cooling
Possible Cause
Compressor not operating
Ambient temperature is too high
Humidity too high when unit is not running
Possible Cause
Unit needs to run to dehumidify
Humidity too high when unit is running and cooling
Possible Cause
Too much moisture in cellar
58
Solution
Add Wine Guardian humidifier or a room
humidifier
Solution
Check wiring for loose, broken or frayed
connections
Check humidistat set up
Check for water flow and solenoid valve
operation
Check for water being hot
Check drip pad – replace if scaled
No vapor barrier around cellar
Solution
Check and reset high limit switch
Clear blockage of condenser airflow
Reduce temperature or draw condenser air from
another space
Solution
Run unit. Seal openings around doors (gasket
and sweep)
Solution
Poor vapor barrier installation
Humidifier malfunction refer to the humidifier
instructions
Add dehumidifier to surrounding space