Wine Guardian SS025 Installation, Operation And Maintenance Manual page 46

Ducted split wine cellar cooling systems
Table of Contents

Advertisement

Settings – Press and hold the "Mode" button for five (5) seconds to access the following
settings.
Deg F or Deg C
Low temperature
alarm set point
High temperature
alarm set point
Low humidity alarm
set point
High humidity alarm
set point
Add or remove
humidifier
Fan AUTO or ON
46
Setting 1
 Press the "Down" arrow to change
temperature from Deg F to Deg C.
Press the "Up" arrow to change temperature
from Deg C to Deg F
.
Setting 2
 Press "Mode" button to advance to Setting 2.
Press the "Up" or "Down" arrow buttons to
adjust to the desired set point. Factory default
is 50 Deg. F.
Setting 3
 Press "Mode" button to advance to Setting 3.
 Press the "Up" or "Down" arrow buttons to
adjust to the desired set point. Factory default
is 65 Deg F.
Setting 4
 Press "Mode" button to advance to Setting 4.
 Press the "Up" or "Down" arrow buttons to
adjust to the desired set point. Factory default
is 5%.
Setting 5
 Press "Mode" button to advance to Setting 5.
 Press the up or down arrow buttons to adjust
to the desired set point. Factory default is
95%.
Setting 6
 Press "Mode" button to advance to Setting 6.
 Press the up or down arrow buttons to adjust
to the desired set point. Factory default is zero
(0).
Zero (0) = No humidifier
One (1) = Stand-alone remote mounted
humidifier
Two (2) = Integral Wine Guardian mounted
humidifier
Setting 7
 Press "Mode" button to advance to Setting 7.
 Press the "Up" or "Down" arrow buttons to
adjust number to the desired set point. Factory
default is zero (0).
Zero (0) = Auto – fan only turns on when
there is a call for cooling or heating
One (1) = Fan On – fan remains on
continuously

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ss050Ss088Ss20015h0128-00Wgs40Wgs75 ... Show all

Table of Contents