quarter inch, a vibration eliminator should be installed close to the motor compressor in a
horizontal parallel to the compressor, crankshaft or in a vertical position 90 degrees to
compressor crankshaft.
NOTE: The suction line should be clamped near the inlet end of the vibration
eliminator. The vibration eliminator is located between the clamp and the
.
compressor

Split System Interconnecting Line Sizing Chart

Table 3
Model
Liquid
Line(OD)
1/4"
SS025
1/4"
SS050
SS088
3/8"
3/8"
SS200
*Interconnecting tube must be reduced down at evaporator connection
Notes:
Line lengths are expressed in equivalent feet = actual run length + fitting allowances (i.e. ~5' for
each bend/elbow allowance).
Use only refrigeration grade dehydrated tubing.
Install refrigeration piping per local codes and ASHRAE guidelines.
Liquid
Suction
connection
line (OD)
at
evaporator
(OD)
1/4"
3/8"
1/4"
1/2"
*1/4"
1/2"
3/8"
7/8"
Min.
Suction
Suction line
connection
insulation
at
thickness
evaporator
(in)
(OD)
3/8"
3/8"
3/8"
*3/8"
5/8"
1/2"
5/8"
*1/2"
Maximum
Maximum
"total" line
lift
length
(height)
50'
15'
50'
15'
50'
15'
50'
15'
33