Download Print this page

Electrolux EDW 1001 Service Manual page 33

Dishwasher

Advertisement

6.14 2YHUYLHZ (UURU 'LVSOD\V
Applicable for EDW1001
'LVSOD\
(UURU 1DPH
3$$ /(' V
L D 9
L D 1 0
Water tap
L D 1 1
closed
L D9
Discharge pump
L D10
L D11
L D 9
L D 10
Aqua-Control
L D 11
L D 9
L D 10
Heating
L D 11
L D 9
L D 10
NTC Sensor
L D 11
L D 9
L D 1 0
L D 1 1
Tacho
L D9
L D10
Recycling pump
L D11
Triac short-
circuit
Programming
error
No displays
when forming
machine models
Calling the Error
Error Display
Memory
visible for
(Customer
Customers
Support)
yes
yes
lit up
flashing
permanently
yes
yes
lit up
flashing
permanently
yes
yes
lit up
flashing
permanently
yes
no
lit up
permanently
yes
no
lit up
permanently
yes
yes
lit up
flashing
permanently
yes
yes
lit up
flashing
permanently
nein
impossible
6KRUW 'HVFULSWLRQ
Filling time exceeded - error is
detected if the switch point of the
pressostat is not reached ...
1) ... after 2min of static filling ...
2) ... after 4min of total filling ...
3) ... after 1min of dynamic filling up
during rinsing ...
Pressostat has not reached point of
return after 2 pumping cycles.
Float switch detects water in the
trough (antirebounding time 2sec.)
Target temperature could not be
reached after 45min.
(Only possible in heating cycles
which are temperature-monitored)
NTC short circuit or break.
NTC is monitored between 1st filling
to start of drying.
When the recycling pump is
controlled, no tacho signal is
detected for 30 secs.
Tacho signals are detected although
the recycling pump is not activated.
Check sum in EEPROM not correct.
Is detected only after start up!
:KDW KDSSHQV
Progr. LED flashing. Program stops.
After remedying the error, the
program can be continued by
pressing the ON/OFF key S0.
Progr. LED flashing. Program stops.
After remedying the error, the
program can be continued by
pressing the ON/OFF key S0.
Program is interrupted.
Valve is closed, and discharge pump
starts up for 1 pumping cycle
(approx. 1min). E
After remedying the error, the
program can be continued by
pressing the ON/OFF key S0.
Program is completed to the end
without activation of the heating
element!
All heating cycles generally take
45min.
Program is completed to the end
without activation of the heating
element!
All heating cycles generally take
45min.
Program stops.
The program can be restarted by
pressing the ON/OFF key S0.
If error occurs several times, you
have to contact the Customer
Support.
The program is interrupted and
water is supplied until the pressostat
function point is reached.
The program can be restarted by
pressing the ON/OFF key S0.
(If error occurs several times, you
have to contact the Customer
Support)
No programs can be selected.
ON/OFF lamp is ON (LD0)

Advertisement

loading

This manual is also suitable for:

Diva