5.2 Water Inlet
The water flows into the regeneration dosage chamber (7) via inlet valve (1), over air break (2), into
regeneration dosage chambers (3) into softener (8). At this point the water divides. 1/4 of the water
enters the tub through the vent (23). 3/4 of the water enters the sump (24) through hose (6).
The level control chamber built into the sump operates the pressure switch (15).
2
4
1
12
6
13
1
Inlet valve
2
Air break
3
Regeneration water dosage
4
Overflow safety level
5
Safety overflow
6
Inlet to sump from regeneration dosage chamber
7
Regeneration dosage chamber
8
Softener
9
Salt container
09.2002 R.K.
3
7
23
11
8
5
10
10
11
12
13
14
15
16
17
15
24
9
Non-return valve salt container
Regeneration valve
Safety inlet hose
Base tray
Float switch
Pressure switch
Filter
Circulation pump
- 15 -
22
21
20
16
17
14
18
Flow heater
19
Drain pump
20
Non-return valve
21
Spray arms
22
Roof-mounted shower
23
Tub vent
24
Sump assembly
599 515 006 EN