To Start Up:
1. Open the LP gas tank valve by turning fully
counterclockwise
2. Move FAN MODE switch to Auto and place
FAN SPEED switch in desired position - Lo
or Hi.
3. Move THERMOSTAT switch from Off to
Heat and press the Temp Selector button
(Up/Down arrows) until the desired tempera-
ture is shown in the display.
4. Furnace fan will start to blow immediately
after setting thermostat.
5. After about 30 seconds, the furnace burner
will light.
6. The furnace will now cycle off and on auto-
matically as the thermostat demands just like
a household furnace.
NOTE: If heat does not come out of the heat
ducts after a minute or so the burner is
not lit. Turn thermostat off for 3-5 min-
utes, check to be sure tank valve is open
and tank is not out of fuel, then try steps
2-4 again. If it still will not light after
three attempts, go to Shut Down steps
and contact your dealer or a local RV
service center.
NOTE: Metal coatings used during manufacture
of the furnace burner parts may smoke
when the furnace is used for the first
time, which may also set off your smoke
alarm. If this happens, provide adequate
ventilation of the smoke to avoid a nui-
sance smoke alarm at this time. We do
not recommend removing the smoke
alarm battery. If it were inadvertently left
disconnected, the smoke alarm would be
inoperative.
To Shut Down:
1. Slide thermostat/system switch OFF.
2. Close LP tank valve.
8-14
For Further Information
Please see the Suburban furnace operating
instructions provided in your Owners InfoCase
for further information, including operating pre-
cautions, and periodic maintenance.

ELECTRONIC THERMOSTAT

(Central Heat/Air Conditioning System)
The thermostat, on the One Place panel, con-
trols heating, air conditioning, cooling fan and
heat pump operation.
Heat Source Switch
ELECTRIC = Heat Pump
GAS = Furnace
NOTE: The thermostat does not automatically
switch between heating and cooling. You
must place the thermostat switch in the
desired position.
Heating:
Slide the thermostat switch to "Gas Heat"
position.
NOTE: Follow proper furnace lighting proce-
dures described previously in this sec-
tion.
NOTE: If your coach is equipped with an
electric Heat Pump, be sure the Thermo-
stat switch is in Gas Heat position. See
Heat Pump for details.