5. Technical Information

General Maintenance

Storage

Hurricane™ Haze 3D User Manual Rev. 1
Do not allow the haze machine to become clogged. After every 40 hours of
continuous operation, use CHAUVET® Fog Cleaner Quart (FCQ) through the system
to prevent the accumulation of particulate matter in the heating element.
The recommended cleaning procedure is as follows:
1.
Unplug the product from power.
2.
Empty all haze fluid from the machine.
3.
Add cleaning solution to the tank.
4.
Connect the product to power and allow it to warm up.
5.
Run the unit in a well-ventilated area until the tank is almost empty.
Note: Do not allow the pump to run dry.
6.
Refill with haze fluid to continue using the hazer. Run the machine briefly to clear
any remaining cleaning solution from the pump and heater.
Note: Do not operate the machine without fluid at any time.
Fog Cleaner Quart (FCQ) was specifically developed by Chauvet to clean your
Hurricane™ Haze 3D. Make sure you use FCQ regularly to increase the life of
your product.
Before storing the hazer, run FCQ through the system as described in the cleaning
procedure above; however, only follow steps 1 through 5. Do not refill the tank with
haze fluid if storing the hazer, but fluid can remain in the line. Cleaning the system
prior to storage will help prevent any particles from condensing inside the pump or
heater while not in use.
Test-run your Hurricane™ Haze 3D on a monthly basis to achieve the best
performance.