T
ECHNICAL
6. T
I
ECHNICAL

Product Maintenance

Do not allow the fog machine to become clogged. After every 40 hours of continuous operation, use
CHAUVET Fog Cleaner Quart (FCQ) through the system to prevent the accumulation of particulate matter
in the heating element.
The recommended cleaning procedure is as follows.
1.
Unplug the product from power.
2.
Empty all fog fluid from the machine.
3.
Add cleaning solution to the tank.
4.
Connect the product to power and allow it to warm up.
5.
Run the unit in a well-ventilated area until the tank is empty.
6.
Refill with fog fluid to continue using the fogger. Run the machine briefly to clear any cleaning
solution from the pump and heater.
FCQ (Fog Cleaner Quart) was specifically developed by CHAUVET to clean
your Vesuvio II. Make sure you use FCQ after every 40 hours of use to increase
the life of your fogger.
Do not spin the fans using compressed air because you could damage the
fogger.
Test-run your Vesuvio II on a monthly basis to achieve the best performance.

Storage

Before storing the fogger, run FCQ through the system as described in the cleaning procedure above;
however, only follow steps 1 through 5. Do not refill the tank with fogger fluid if storing the fogger. Cleaning
the system prior to storage will help prevent any particles from condensing inside the pump or heater while