Hc-T Wired Timer Remote Operation - Chauvet Hurricane Haze 3D User Manual

Chauvet hurricane haze 3d fog machine user manual
Table of Contents

Advertisement

HC-T Wired
Timer
Remote
Operation
1.
Connect the Hurricane™ Haze 3D to power and turn the power switch to the on position.
2.
Plug the HC-T timer controller into the wired remote controller socket on the back of the haze machine.
3.
Press the <TIMER ON/OFF> latching button on the HC-T. The Timer LED Indicator above the button will
light up. The <TIMER ON/OFF> latching button will remain on until it is pressed again.
4.
Set the INTERVAL, DURATION, and OUTPUT adjustment knobs to the desired positions.
·
INTERVAL knob sets the amount of time in between bursts of haze.
·
DURATION knob sets the length of time that the haze machine will run during the burst.
·
OUTPUT knob adjusts the haze output.
5.
Press the <CONTINUOUS> latching button and the haze machine outputs haze until the button is
pressed again. The Manual/Power LED Indicator above the button will light up during continuous
operation.
Note: The duration of continuous haze output is based on the capability of the haze machine.
6.
Press the <MANUAL> button to momentarily output haze. The haze machine will output haze for as long
as you hold down the button. During manual operation the Manual Momentary LED Indicator above the
button will light up.
Note: The duration of manual haze output is based on the capability of the haze machine.
When using the manual button, it may take a few seconds for the hazer to respond
because the fan is building up speed.
Interval
Adjustment
Timer LED
Indicator
Manual/Power
LED
Timer On/Off
Latching Button
Hurricane™ Haze 3D User Manual Rev. 1
The HC-T wired timer controller allows you to automatically trigger haze output by
setting interval and duration times. LED indicator lights display the machine and
controller's current state. Rotary knobs set interval and duration times, while manual
and continuous buttons allow overriding control.
Using the Control Panel, set the Haze Volume and Blower Speed output to x000
prior to connecting the HC-T. You can then connect and operate the HC-T with
the Hurricane™ Haze 3D.
OUTPUT
Duration
Adjustment
Output
Adjustment
Manual
Momentary LED
Manual Control
Momentary Button
Continuous
Latching Button
Page 11 of 16