FIGURE 3-3
For more details on the operator panel see
Overview" on page
4. Turn on the input power.
Note – Wait at least 30 seconds before turning on the system power that you turned
off, by pulling out the power cord or using the circuit breakers on the distribution
panel.
Refer to the manual that shipped with the input power source for instructions.
5. Watch the administration console for error messages as the XSCF Unit powers
on.
See
6. Confirm that the XSCF STANDBY LED (green) on the operator panel is lit.
7. When the login prompt appears, enter default for the login name:
login: default
Note – Step 8 must be performed within a minute of Step 7 or the login certification
will time out.
8. Set the mode switch on the operator panel to the Locked position.
9. Press the RETURN key.
Wait five seconds before continuing to Step 10.
10. Set the mode switch on the operator panel to the Service position.
11. Press the RETURN key.
3-8
SPARC Enterprise M4000/M5000 Servers Installation Guide • February 2012
Operator Panel Mode Switch
A-9.
Appendix
B,
Fault Isolation
Section A.3, "Operator Panel
for fault information.