Top Heating Surfaces And Linkage - Baxi Bioflo User Operating Instructions Manual

Pellet central heating system boiler
Table of Contents

Advertisement

Care, cleaning and maintenance
3.8

Top heating surfaces and linkage

These parts are automatically checked and cleaned as part of the annual maintenance by heatteam, the
service division of BAXI Group
Always switch the boiler off first with the ON/OFF button (Fig. 88) and wait until burnout mode has finis-
hed. It is essential to let the boiler cool down before cleaning.
– Remove the front cover (tip: open the cover of the reserve supply container first) – Fig. 89.
Fig. 88
Switching off FireWIN
– Unscrew two wing nuts from the heating surface cover and remove the complete cover – Fig. 90.
– Remove the jet protection plate (tip: vacuum out fly ash first using a vacuum cleaner) – Fig. 91.
Fig. 90
Removing the wing nuts and cover
– Vacuum down the top heating surfaces and linkage or clean with a cleaning brush – Fig. 92.
– Push on the cleaning lever of the heating surfaces at the right side and move it forwards and backwards seve-
ral times –– Fig. 93
Fig. 92
Cleaning top heating surfaces and linkage
–– Empty the ash pan for the heating surfaces (accessory) or remove the ash from the duct – Fig. 94.
Fig. 94
Removing the ash pan(s) or removing the ash
Fig. 89
Removing the cover
Fig. 91
Removing the jet protection plate
Fig. 93
Connecting the lever and operating it several times
37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bioflo 12 kw pear

Table of Contents