4.3

Fault messages

Code Meaning/effect
Monitoring of the auger conveyor
is defective
FE 206
Press Reset.
Combustion chamber pressure
not stable
FE 356
Press Reset.
Cause/remedy
The boiler is in operation.
Press the Reset button. If the fault reoccurs after a reset, inform BAXI Custo-
mer Service or a heating technician.
The boiler is in operation.
a) Heating surface cover leaking, check whether this is firmly closed (see sec-
tion 3.8), press the Reset button.
b) Combustion chamber and ash door are leaking – check the seal, replace
the seal if necessary, press the reset button.
c) Pressure measuring nipple of combustion chamber pressure switch is blok-
ked – clear it (see section 3.9.1), press the reset button.
d) Intake air line or induction opening at rear is blocked – clear it and press
the reset button.
e) Exhaust pipe or flue is blocked, clear it and press the reset button.
f) Combustion chamber pressure switch is defective, inform BAXI Customer
Service or a heating technician.