Care, cleaning and maintenance
Fig. 98

3.9.3 Blower wheel, blower box and exhaust pipe to flue

– Unscrew two wing nuts from the exhaust pipe and remove the cleaning cover (Fig. 99). Clean fly ash out of the
exhaust pipe with a vacuum cleaner. Close the cleaning cover again.
– Disconnect the blower plug – Fig. 100.
Fig. 99
– Unscrew two wing nuts from the blower box and remove the complete blower unit – Fig. 101.
– Clean the blower wheel using a spatula and brush – Fig. 102.
– Inside of blower box: Clean fly ash with a vacuum cleaner.
Fig. 101
Assembly:
– Guide the blower unit in at the back using the stay bolts and attach at the front with two wing nuts.
– Reconnect the blower plug.
– Close the control panel, connect the securing mechanism and mains power plug at the top using a screw and
hook in the side panel.
Removing dust from the rotary feeder
Removing the wing nuts and cleaning
opening – cleaning the exhaust pipe
Removing wing nuts, removing the
blower unit
Screw plug
Fig. 100
Disconnecting the blower
plug