why will my bermuda bbu15e not fire up from cold the burner tries to ignite but faults E133
2 comments:
Mr. Anderson
February 23, 2025
The Baxi Bermuda BBU 15 HE shows fault code E133 due to an interruption of the gas supply or flame failure. If the boiler does not fire up from cold and displays this error, possible causes include:
1. No gas supply – The gas supply to the boiler may be turned off or interrupted. 2. Flame failure – The burner may not be igniting properly due to a fault with the ignition system. 3. Blocked or faulty gas valve – The gas valve may not be opening correctly to allow gas flow. 4. Air in the gas supply – If the system has recently been worked on, air pockets may prevent ignition.
To resolve the issue, check that the gas supply is on, reset the boiler by holding the reset switch for at least 5 seconds, and ensure there are no blockages in the gas line. If the problem persists, professional servicing may be required.
Page 1
Installation & Servicing Instructions Baxi Bermuda BBU 15 HE Condensing Back Boiler Unit These Instructions must be read in conjunction with those for the separate Valor Dimension electric firefront. They include the Benchmark Commissioning Checklist and should be left with the user for safe keeping.
1.0 Introduction Description 1. The Baxi Bermuda BBU 15 HE is a central heating boiler designed for installation within a builders opening in the living space of a dwelling. 2. The boiler is a fully automatic gas fired condensing boiler. It is room sealed and fan assisted.
7.0 Installation INSTALLATION SEQUENCE There are 4 main elements to the installation of the Baxi Bermuda BBU 15 HE:- • Preparation of pipework & opening • Inserting the flue into the chimney • Siting & fixing the boiler • Fitting the terminal assembly...
GAS BOILER SYSTEM COMMISSIONING CHECKLIST This Commissioning Checklist is to be completed in full by the competent person who commissioned the boiler as a means of demonstrating compliance with the appropriate Building Regulations and then handed to the customer to keep for future reference. Failure to install and commission this equipment to the manufacturer’s instructions may invalidate the warranty but does not affect statutory rights.
SERVICE RECORD It is recommended that your heating system is serviced regularly and that the appropriate Service Record is completed. Service Provider Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s instructions.
Standard Warranty Terms & Conditions To activate your second year free warranty you must register your boiler with heateam the service division of Baxi Heating UK Ltd either by completing and returning the registration card or calling our telephone registration line on 0800 013 7989.
Need help?
Do you have a question about the Bermuda BBU 15 HE and is the answer not in the manual?
Questions and answers
why will my bermuda bbu15e not fire up from cold the burner tries to ignite but faults E133
The Baxi Bermuda BBU 15 HE shows fault code E133 due to an interruption of the gas supply or flame failure. If the boiler does not fire up from cold and displays this error, possible causes include:
1. No gas supply – The gas supply to the boiler may be turned off or interrupted.
2. Flame failure – The burner may not be igniting properly due to a fault with the ignition system.
3. Blocked or faulty gas valve – The gas valve may not be opening correctly to allow gas flow.
4. Air in the gas supply – If the system has recently been worked on, air pockets may prevent ignition.
To resolve the issue, check that the gas supply is on, reset the boiler by holding the reset switch for at least 5 seconds, and ensure there are no blockages in the gas line. If the problem persists, professional servicing may be required.