Operation
2.4

Info panel

The Info panel is located at the top under the glass cover. Press the locking button at the front and fold the glass
cover open, the Info panel pops up automatically – Figs. 8, 9. It consists of a large full text display, an ON/OFF
button with an LED signal lamp indicating Operation (green) or Malfunction (red), a button for manual opera-
tion / flue cleaning function as well as four individual menu buttons. The function of each menu button is display-
ed on the Menu line.
Fig. 8
Signal lamp (LED)
„Operation" – green;
„Malfunction" – red
ON/OFF button
Operating
phases
displayed here, including
Standby, Burner OFF , etc.
Menu line
Fig. 10
Info panel
The various operating modes are displayed on Info panel together with the corresponding operating phases.
The following operating modes exist:
– OFF
– ON (with self-test, lighting ON, lighting OFF)
– Pellet feed
– Solid fuel / buffer mode
– Manual operation
– Flue cleaning function
– Shutdown procedure
Press the locking button
are
Fig. 9
Boiler temperature
38
°C
Standby
Info
Menu
RESET
Menu buttons
12
Info panel pops up
Full-text display
(illuminated display)
Manual operation / flue cleaning
function
5s
Assignment of buttons to
their specific function
Corresponding operating phases:
– Standby
– Purging
– Ignition phase
– Flame stabilisation
– Modulation mode
– Burnout
– Burner OFF
– Switch off heat generator

Advertisement