Further notes.

Use a cutting spray when working.
When the power supply is disconnected
while the motor is running or when the
switched-on power tool is plugged in, the
motor will not restart.
When the application tool continuously
blocks or is subject to overload, the motor
stops automatically. Restart the motor again.
Carry out core-drilling processes without
interruption, if possible. To complete a
started and interrupted drilling run, repeat the
center-drilling process.
Repair and customer service.
Before mounting or replacing application tools or accessories, pull the power
WARNING
plug. This preventive safety measure rules out the danger of injuries through
accidental starting of the power tool.
Exchangeable parts
If required, you can change the following
parts yourself:
Auxiliary handle, application tools
Service.
Have maintenance carried out
WARNING
only through qualified person-
nel. Incorrectly mounted leads and compo-
nents can cause serious injuries. Have the
required service carried out only through a
FEIN customer service agent.
Cleaning.
Prior to any cleaning or main-
WARNING
tenance, disconnect the power
tool from the power supply in order to avoid
accidents.
When using in environments
WARNING
with conductive dust in the air,
such as when working metals, this dust can
settle in the interior of the power tool. This
can impair the total insulation of the power
tool. Therefore, regularly blow out the interior
Replace dull pilot bits; they may not be
reground.
Remove the chippings and the drilled core
after each drilling process.
Chippings and the core are
CAUTION
sharp and hot!
When changing a drill bit, pay attention not to
damage the cutting edges.
When core drilling layered material, remove
the core and the chippings after drilling each
layer.
of the power tool from outside via the ventila-
tion openings with dry, oil-free compressed
air; always wear eye protection when doing
this. For additional protection, connect a
ground fault circuit interrupter (g.f.c.i.) on the
line side.
Do not attempt to clean
CAUTION
clogged or dirty ventilation
openings of the power tool with pointed
metal objects; use non-metal tools or objects
for this.
Do not use cleaning agents
CAUTION
and solvents that can cause
damage to plastic parts. These include: Gaso-
line, carbon-tetrachloride, chloric solvents,
ammonia and domestic cleaning agents that
contain ammonia.
If the supply cable of this
CAUTION
power tool is damaged, it
must be replaced by a specially prepared cable
available through the FEIN customer service
center.