LD
Series
SAMPLE
TP-114
Air Metering Orifice
DO NOT REMOVE
TP-3014
RE-VERBER-RAY INFRA-RED RADIANT TUBE HEATER
FOR INDOOR INSTALLATION ONLY
MODEL NO.
HOT
120V
AG1 - 40 - 125N
LD-20-40N
NEUTRAL
EARTH
DESIGN COMPLIES WITH:
ANSI Z83.20b-2003-GAS FIRED LOW INTENSITY INFRA-RED HTR.
- 120V HEATER INPUT -
VOLTS AC
60Hz
AMPS - Starting
AMPS - Running
Heater Type:
DETROIT RADIANT PRODUCTS CO.
21400 HOOVER ROAD - WARREN, MI 48089
(586) 756-0950
www.reverberray.com
HOT
120V
NEUTRAL
EARTH
- 120V HEATER INPUT -
F/N: LLV3EP1
Left Panel
(Fan Compartment)
This heater is equipped with an
HLRB Relay(s) required for grouping
multiple heaters on the same
thermostat. This heater must be wired with a
field supplied transformer in accordance with
the installation, operation manual.
F/N: LLTB031
(Models with optional relay
board installed only).
LD-20-40 N
Production Code:
LD-40
Version:
5.05
Data on this label is for the model shown on this label. If your heater has been converted,
this information is not accurate. Please contact the factory for assistance.
BURNER COMPONENTS:
(Specify TP-#'s)
Gas Valve:
36E96-224-N
840A
Circuit Board:
Micro 60-24
851
Wire Harness:
3 PCS Harness
852
N.O. Switch:
None
N/A
N.O. VL Orifice:
None
N.C. Switch:
None
N/A
N.C. VL Orifice:
None
Diff Switch:
IS22016051F5169
264E
Diff VL Orifice:
Grey (+ / -)
Igniter:
Norton
50
Burner:
High
201B
16" Tube:
4" Gen.
1080
Ind. Lights:
Yellow - 120V
828
HEATER
Orifice Type:
C1
C2
TYPE:
Gas:
TP-204#
3
C1
Air:
TP-44#
1 1/2"
1 5/8"
For parts replacement information, contact factory at 586-756-0950 or visit www.drp-co.com/parts.
Burner Control Box
Component Label
(located under the top panel)
F/N: LLAC
1 - 1/2"
Air Metering Orifice
INPUT BTU/H
FOR USE WITH
40,000
125,000
NAT GAS
Manifold Pressure
3.5in.
W.C.P.
Max. Inlet Pressure
14.0in.
W.C.P.
Min. Inlet Pressure for
5.0in.
W.C.P.
120V
Purpose of Input Adjustment
Min. Mounting Angle
0 DEGREES
4.8
Max. Mounting Angle
45 DEGREES
1.1
Combustion Chamber
3
C1
4" BC Aluminized
For Stainless Steel Upgrades the Combustion Table is upgraded to 409 Stainless Steel
Serial No. 0603DETR12345 0001
Back Panel
F/N: LLTB018 (NG)
F/N:
LLTB019 (LP)
This heater has a 24 Volt
control system. Do not
connect 120 Volt power
supply, as it will damage
the controls.
Top Panel
Serial No.: 0804XXXXXXXXXX 0001
Stock:
None
Add-On:
N/A
Diag. Light:
Red LED
Term. Block:
None
N/A
Transformer:
40 VA
N/A
Fan:
Fasco Lg.
55A
Alt. Fan:
50Hz - 120V
55B
Alt. Fan Usage:
When Specified
Relay:
None
N/A
Filter:
None
N/A
24 Volt In:
3 T-plug
832
120 Volt In:
120V Cord
333
Gas In:
7/8" FC Flare
83
Extra VL Orifice:
None
Internal Use Only:
C3
3
1
Electric:
LLWT038
Special 1:
17
Tag:
1 5/8"
None
Special 2:
1 7/16"
1.0
CAUTION
!
Provide 24
Volts Only
This heater has a 24 Volt
control system. Do not
connect 120 Volt power
supply, as it will damage
the controls.
F/N: LLDR003
(Models with optional
relay board installed only)
CAUTION
!
Provide 24
Volts Only
24V
F/N: LLV3EP4
White Crescent
H
HIGH
FIRE
F/N: LLV2EP9
LED CODE
Initial Flash on power up,
then steady off
Steady on
1 flash
2 flashes
3 flashes
4 flashes
No flash on 117V start-up
Bottom Panel
5
Introduction • Safety Signs and Labels
RE-VERBER-RAY INFRA-RED RADIANT TUBE HEATER
®
FOR INDOOR INSTALLATION ONLY.
Class IIIA Permanent Label
MODEL NO.
INPUT BTU/H
LD-20-40N
40,000
Volts AC:
Manifold Pressure:
120V - 60Hz
3.5 in.
W.C.P.
AMPS - Starting:
Maximum Inlet Pressure:
4.8
14 in.
W.C.P.
AMPS - Running:
Minimum Inlet Pressure:
1.1
5.0 in.
W.C.P.
Combustion Chamber:
4" Black Coated Aluminized
DESIGN COMPLIES WITH:
ANSI Z83.20b-2003-GAS FIRED LOW INTENSITY INFRA-RED HTR.
DETROIT RADIANT PRODUCTS COMPANY
21400 HOOVER ROAD - WARREN, MI
(586) 756-0950
-
www.drp-co.com
HIGH
LOW
24V OUT
- 24V HEATER OUTPUT -
F/N: LLV3EP2
Orange Crescent
(Models with optional
relay board installed
L
only).
LOW
FIRE
FAULT STATUS
Normal operation
Module failure/Internal fault
Ignition failure
APS 1 failure
APS 2 failure
Solenoid valve fault/Leaky valve/
Flame amplifier fault
Transformer fault
F/N: LLTB007(1)
F/N: LLTCL006 - Clearance
to Combustibles Label.
F/N: LLLOGO1
FOR USE WITH
Natural Gas
Heater Type
C1
Minimum Mounting Angle:
0
DEGREES
Maximum Mounting Angle:
45
DEGREES
Serial No.: 0807XXXXXXXXXX 0001
Rating Plate
FAULT CODE DELAY
Immediate
Immediate
32 minutes
12 minutes
22 minutes
Immediate
Immediate

Hide quick links: