To assemble the baffles: NOTE: Baffles may be inserted into the tube while being assembled.
Identify one heat baffle (no fins) and two pressure baffles (with fins).
1
Orient the baffle tabs at a 90° angle to the baffle keyhole (see Figure 3.18).
2
Insert one baffle tab into keyhole and slide completely to one side until both baffle tabs appear in
3
the keyhole.
Adjust the tabs to the center of the keyhole and rotate the baffle 90 degrees to lock the baffle
4
sections together.
Repeat this process until all three baffle sections are connected.
5
Figure 3.18
Assembling the Baffles
Baffle tabs
Baffle keyhole
To insert the baffles:
Insert baffles with the keyhole end first. IMPORTANT: Note insertion order and proper fin direction
1
(80° towards exhaust end and 100° towards burner end (Figure 3.19).
Rotate baffle assembly so that it is in the vertical position.
2
Slide baffle assembly into the last radiant tube section, furthest from burner control box.
3
NOTE: It may be necessary to cut the heat baffle into two sections when the heater is configured with a 'U' or
'L' shaped accessory fitting. In this case, place as much baffle as possible downstream of the 'U' or 'L' fitting
and the remainder just before the fitting.
Figure 3.19
Inserting the Baffles
2
Completed assembly
Heat baffle
Keyhole
IMPORTANT: Baffle assembly must be flush with the end of
the last tube section (exhaust end) and in the vertical position.
22
3
Pressure baffle
100° 80°
Turbulator fins
LD
Series
4
Pressure baffle