9-7. Abnormal Test Results

No.
Part
1
PC1
Short
2
PLF1
L-L short
3
PLF1
R-R short
4
PD1
L- +/- short
5
PD1
+ - - short
6
PC2
Short
7
PD2
Short
8
PC5
Short
9
PQ1
D-G short
10
PQ1
D-S short
11
PQ1
G-S short
12
PC7
Short
13
PD3
Short
14
PU1
1-2 short
15
PU1
2-3 short
16
PU1
3-4 short
17
PU1
5-6 short
18
PU1
6-7 Short
19
PU1
7-8 short
20
PU2
K-R short
21
PU2
A-R short
22
PU2
A-K short
23
PU3
3-4 short
24
PC9
Short
25
PC10
Short
26
PC12
Short
27
PC8
Short
28
PR1
Open
29
PR2
Open
30
PR3
Open
31
PR5
Open
32
PR6
Open
33
PR7
Open
34
PR8
Open
35
PR9
Open
36
PD4
Short
37
PD5
Short
38
PC11
Short
39
PC13
Short
(Primary power supply circuit on Main Control CPB Ass'y)
Fault
PF2 Fuse blown
PF2 fuse blown and PLF1 damaged
PF2 fuse blown and PLF1 damaged
PF2 fuse blown and PLF1 damaged
PF2 fuse blown and PLF1 PQ1 damaged
PF2 fuse blown and PLF1 PQ1 damaged
PF2 fuse blown and PLF1 PQ1 damaged
PF2 fuse blown and PLF1 PQ1 damaged
PF2 fuse blown and PLF1 PQ1 damaged
PR7 damaged
PR7 damaged
PR7 damaged
PF1 fuse blown
Result
Output
No output
Normal
Normal
No output
No output
No output
No output
No output
No output
No output
No output
No output
No output
No output
No output
No output
No output
No output
Normal
No output
No output
No output
No output
No output
No output
No output
No output
No output
Normal
No output
Normal
No output
No output
No output
Normal
No output
No output
No output
No 12V