Basic Plumbing; Non-Booster Pump Pressure-Side Pool Cleaner Plumbing - Jandy AquaLink RS Installation Manual

All button and onetouch control panels
Hide thumbs Also See for AquaLink RS:
Table of Contents

Advertisement

Plumbing for Pool and Spa Combination.
The diagram to the right shows a simplified version of a
standard plumbing setup for a pool and spa that share
the same filter pump, filter, and heater. The Intake and
Return JVAs (Jandy Valve Actuators) turn simultaneously
so when the Spa button is pressed on the AquaLink
Controller, water circulation switches between pool and
spa. Consult the JVA Installation Manual to ensure that the
Jandy Valve Actuators are "in synch" and rotate properly.
Please also note that if you have a pool only or a spa only,
the diagram does not apply, and if your pool and spa have
separate sets of equipment, you should install an
®
AquaLink
RS 2/6 model Controller, designed to control
separate equipment sets.
Non-Booster Pump Pressure-Side
Pool Cleaner Plumbing.
The diagram to the right shows standard
plumbing for a non-booster pump pressure-side
pool cleaner (i.e., Ray-Vac, Energy Sweep, etc.) To
control this cleaner, control water circulation to
the cleaner by using a Cleaner JVA (see right).
Plumb a three-port valve between the filter pump
and the filter. Install a 2-port valve to open and
close the cleaner line, and after the valve, install a
Jandy Energy Filter to provide filtration (as the
main filter has been bypassed). Mount a JVA on
the 2-port valve and set the cam(s) (see JVA
Manual) to turn 90º. Please note the installation of
a non-booster pump pool cleaner requires
moving DIP Switch #1 to the ON position.

Basic Plumbing

®