Jandy AquaLink RS6 Installation Manual

Jandy AquaLink RS6 Installation Manual

Dual equipment systems
Hide thumbs Also See for AquaLink RS6:

Advertisement

Installation Data
Installation Manual
AquaLink
All Button and
OneTouch
Control Systems
Dual Equipment Systems
FOR YOUR SAFETY - This product must be installed and serviced by a professional pool/
spa service technician. The procedures in this manual must be followed exactly. Failure to
follow warning notices and instructions may result in property damage, serious injury, or
death.
RS
®
TM
WARNING

Advertisement

Table of Contents
loading

Summary of Contents for Jandy AquaLink RS6

  • Page 1 Installation Data Installation Manual AquaLink ® All Button and OneTouch Control Systems Dual Equipment Systems WARNING FOR YOUR SAFETY - This product must be installed and serviced by a professional pool/ spa service technician. The procedures in this manual must be followed exactly. Failure to follow warning notices and instructions may result in property damage, serious injury, or death.
  • Page 3: Table Of Contents

    Page 3 Table of Contents Section 1. Important Safety Instructions ..4 Section 2. System Overview ......6 2.1 Package Contents ..........6 2.2 System Component Specifications and Dimensions..........7 2.3 Plumbing Diagrams ..........8 Section 3. Power Center Connection (Low Voltage) ......... 9 3.1 Connecting Power and Mounting Bezel .....
  • Page 4: Section 1. Important Safety Instructions

    Page 4 Section 1. Important Safety Instructions READ AND FOLLOW ALL INSTRUCTIONS Lire la notice technique. All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes. When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: DANGER To reduce the risk of injury, do not remove the suction fittings of your spa or hot tub.
  • Page 5 Page 5 WARNING People with infectious diseases should not use a spa or hot tub. To avoid injury, exercise care when entering or exiting the spa or hot tub. Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible drowning.
  • Page 6: Section 2. System Overview

    Page 6 Section 2. System Overview Package Contents Package contents will depend on which AquaLink RS System you are installing. All Jandy AquaLink RS Systems come complete with the appropriate number of 3HP relays needed. Control System Sub-Assemblies All Button Dual Equipment...
  • Page 7: System Component Specifications And Dimensions

    Page 7 2.2 System Component Specifications and Dimensions Specifications (USA and Canada) Power Supply 120 VAC; 60 Hz; 3 A Contact Rating High voltage - 25 A; 3HP @ 240 VAC 1½ HP @120 VAC 1500 Watts Incandescent Low Voltage - Class 2, 1 A @ 24 VAC Emergency Service Switch All Circuits (located at Power Center in Service Mode) Specifications (European)
  • Page 8: Plumbing Diagrams

    Page 8 Plumbing Diagrams 2.3.1 Basic Plumbing Refer to Figure 1 when plumbing two separate sets of equipment. The basic setup consists of one pump, filter and heater for the pool and another set for the spa. Pool Heater Spa Heater Pump Pool Pump...
  • Page 9: Section 3. Power Center Connection (Low Voltage)

    Page 9 Section 3. Power Center Connecting Control Panel Cable to Connection Make provisions for Jandy Control Panel (Low Voltage) Cable to be run between the Control Panel and the Power Center. Connecting Power and Mounting NOTE When cable will be run underground or in Bezel concrete, it must be run in conduit.
  • Page 10: Connecting Heater To Low Voltage Terminal

    24 VAC or less. door (see Section 5, Figure 5). 1. If you are connecting a Low Voltage pool heater (for example, a Jandy Brand heater), NOTE Pool filter pump socket is on the far left of the connect two 14 gauge wires, designed...
  • Page 11: Section 4. Power Center Pcb Dip Switch Settings

    JVA into the cleaner JVA socket. Turn ON DIP Switch #1. S1 DIP #5 ON- Factory Use Only • Main filter pump turns on whenever cleaner This switch is used for calibration by Jandy turns on. certified technicians only (will momentarily • Cleaner will not turn on until filter pump display the solar temperature and if installed, actual has been on for three (3) minutes (to ensure FlowLink water pressure).
  • Page 12: Dip Switch Settings For Pool And Spa Combination

    Page 12 OFF ON 4 3 2 1 4 3 2 1 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1 RESET AUTO SERVICE TIME OUT DIP Switch Settings for Pool and Spa Combination S1 DIP Switch # AUX1= any equipment AUX1= Pool Cleaner...
  • Page 13: Dip Switch Settings For Pool Or Spa Only

    Page 13 DIP Switch Settings for Pool or Spa Only S1 DIP Switch # AUX1= any equipment AUX1= Pool Cleaner AUX2= any equipment AUX2= Low Speed for a two-speed filter pump. Filter pump circuit becomes High Speed. AUX3= any equipment No change Heater cool down operates.
  • Page 14: Section 5. Dual Equipment Wiring Diagram

    Page 14 Section 5. Dual Equipment Wiring Diagram AquaLink RS 2/6, 2/10, 2/14, 2/22, 2/30 Wiring Diagram ® For Optional Multiplex PCB Service Controller Connector Connect red four-pin connector to Multiplex Board S1 DIP SWITCH SETTINGS Factory Setting When Turned Aux1 Cleaner 4 3 2 1...
  • Page 15 Page 15 NOTES...
  • Page 16 If the dealer is not available, you can locate a service center in your area by visiting www.jandy.com or by calling our technical support department at 1.800.822.7933 in the United States or 1.888.647.4004 in Canada. All returned parts must have a Returned Material Authorization number to be evaluated under the terms of this warranty.