All Button Control Panel Programming and System Defaults

Basic Programming.

To set a particular piece of equipment to turn on and off at
predetermined timeS, press the MENU button, scroll to the PROGRAM
MENU, press ENTER, and then press the button for the equipment that
you want to program. The Controller Display will ask you to enter the
day. Use the arrow keys <—>* to select, and press ENTER. The display
will now ask you for the starting time and ending time. Repeat this
process for each piece of equipment that you wish to program. You may
enter as many programs as needed for each piece of equipment.
Set the Time.
To set the time, press the Menu button. Use the arrow keys to scroll to
the SET TIME Menu and press ENTER. Now scroll to the correct year
and month and press ENTER. Scroll to the correct hour and minute and
press ENTER.
Depending on the age of the AquaLink RS, the following items can be
found either in the Main Menu or in a Sub Menu under SETUP:

Set the Temperature.

Press the MENU button, scroll to the SET TEMP Menu item and press
ENTER. Use the arrow keys to select POOL or SPA and again, press
ENTER. Once you have selected which heater to set the temperature for,
use the arrow keys to move to the desired temperature, and press
ENTER, to complete.
Label Auxiliary Functions.
To label Auxiliary functions, press the MENU button. Scroll to SYSTEM
SETUP and press ENTER, then scroll to the LABEL AUX Menu and
press ENTER. Press the button to be labeled (example: AUX 1). Scroll
to the desired label and press ENTER. Repeat for all functions.
NOTE 1: The labels "TIMED AUX", "AIR BLOWER", and "FILL LINE" are
30 minute timed circuits. NOTE 2: If DIP switch 1, 2 or 3 are on,
Auxiliaries 1, 2 and 3 are labeled CLEANER, LOW SPEED and
SPILLOVER respectively and cannot be relabeled.
Set Spa side Switch or SpaLink RS Functions.
The buttons on the Spa Side Switch or the SpaLink RS may be set to
control any functions the home owner wishes. To the right is a list of
default settings for the Switch. If you wish to change which functions the
Switch(es) control, first press the MENU button. Scroll to SYSTEM
SETUP and press ENTER, then scroll to FOUR FUNCTION SWITCH
(SPA SWITCH on Rev. G or higher) or SPA LINK and press ENTER.
Follow the prompts to assign each REMOTE button.
Set Freeze Protection.
AquaLink RS Freeze Protection senses when the air temperature falls
below 38º F and automatically turns on the filter pump to circulate the
water, thus preventing freezing of pipes. To add freeze protection to
other equipment, press the MENU button. Scroll to SYSTEM SETUP
and press ENTER, then scroll to FRZ PROTECT and press ENTER.
Press the button for the equipment you want to protect.
Assign JVAs.
The Assign JVAs Menu lets you assign Jandy Valve Actuators (JVAs)
to any auxiliary button. This means that whenever you press that
auxiliary button, a valve turns. On pool/spa combination models,
there are two JVA Valve Actuators that can be assigned to auxiliary
buttons: the Cleaner JVA and the Solar JVA. On pool only/spa only
models, there are four JVAs available. The AquaLink RS installer
must set up these JVAs for this feature to operate correctly.
Assigning JVAs lets the owner control certain features like
diverting water to a waterfall or bank of spa jets.
19
Default Time
Default Time - 1:00 P.M.
Default Day - MONDAY
Default Date - 01/31/00
Default Temperature
Default Pool Temp - 80ºF.
Default Spa Temp - 102ºF.
Default Temperature
Default Switch Setting
Button 1 - Spa (Filter Pump)*
Button 2 - Spa Heater (Temp1)*
Button 3 - AUX 1
Button 4 - AUX 2
* pool/spa only controls.
Default Freeze Protect. Settings
FILTER PUMP: Freeze Protection ON. ALL OTHER
EQUIPMENT, Freeze Protection OFF.
NOTE: If you select SPA to be freeze protected,
water circulation will switch between pool and spa
every 30 minutes during freezing conditions once
freeze mode is active.
How to assign values:
1. Press the MENU button. Use the FORWARD and BACK
buttons to move to SYSTEM SETUP. Press ENTER. Use
FORWARD button to move to ASSIGN JVAs Menu and
press ENTER. The AquaLink RS display will read
CLEANER JVA <—>*. If both JVAs are being used, you
will not be able to use this Menu.
2. Use the FORWARD and BACK arrows to choose
among the JVA's listed. When the JVA you want to assign
to an auxiliary is displayed, press ENTER.
3. The AquaLink RS display will read SELECT AUX TO
ASSIGN JVA TO. Press the button of the Auxiliary
that you want to activate the JVA.