9-32 SERVICING INFORMATION
SHAFT DRIVE
ITEM
Secondary bevel gear backlash
Final bevel gear backlash
Damper spring free length
CARBURETOR
ITEM
Carburetor type
Bore size
I.D. No.
Idle r/min.
Fuel level
Float height
Main jet
Main air jet
Jet needle
Needle jet
Throttle valve
Pilot jet
Pilot screw
Throttle cable play
THERMOSTAT + RADIATOR + FAN + ENGINE COOLANT
ITEM
Thermostat valve opening
temperature
Thermostat valve lift
Engine coolant temp. switch
operating temperature
Radiator cap valve opening
pressure
Cooling fan thermoswitch
operating temperature
Engine coolant type
Engine coolant capacity
Drive side
E-02, 19, 24
MIKUNI BDSR34
34 mm
41F1
1 100 ± 100 r/min.
7.0 ± 0.5 mm
(2.76 ± 0.02 in)
(M.J.)
#132.5
φ 1.8
(M.A.J.)
(J.N.)
5E22-3
(N.J.)
P-0M
(Th.V.)
#95
(P.J.)
#27.5
(P.S.)
PRE-SET
(3.0 turns back)
2 – 4 mm
(0.08 ± 0.16 in)
STANDARD/SPECIFICATION
Approximately 75 °C (167 °F)
Over 6 mm (0.24 in) at 90 °C (194 °F)
OFF → ON
ON → OFF
(0.95 – 1.25 kgf/cm
OFF → ON
ON → OFF
Use an antifreeze/coolant compatible with alumi-
num radiators, mixed with distilled water only, at
the ratio of 50:50
STANDARD
0.05 – 0.32
(0.002 – 0.013)
0.03 – 0.064
(0.001 – 0.025)
———
SPECIFICATION
E-03, 28
41F2
#
5E23
#
PRE-SET
Approximately 120°C (248°F)
Approximately 113°C (235.4°F)
95 – 125 kPa
2
, 13.5 – 17.8 psi)
Approximately 105°C (221°F)
Approximately 100°C (212°F)
1 500 ml
(1.6 US qt, 1.3 lmp qt)
Unit: mm (in)
LIMIT
———
———
58.5
(2.30)
E-33
41F3
LIMIT
———
———
———
———
———
———
———
———
———