Table 2: Causes of Trouble Beeps
There is a problem with how the sensor is communicating with the panel.
1. Test the sensor as described in "Sensor Test."
2. If the sensor does not test OK, call your security dealer for service.
A sensor may have an internal problem or a fire/smoke sensor may not have properly reset after
activation, or the sensing chamber may be dirty or partially obstructed.
1. Test the sensor as described in "Sensor Test."
2. If testing the sensor does not clear the trouble condition, call your security dealer for service.
A sensor has a low battery.
1. Disarm the system.
2. Remove the sensor cover. If the battery is an Alkaline AAA or AA, change the battery(s). If the bat-
tery is any other type, call your security dealer for service.
A sensor cover is off or open. Secure the cover and trip the sensor to clear the tamper condition.
The system can't communicate with the central monitoring station. The system tries to report to the
central station three times before indicating Phone Failure Trouble, then makes five more reporting
attempts.
1. Make sure the panel is connected to the special phone jack installed by your security dealer.
2. Disconnect the panel from the special phone jack and check phones for dial tone. If you hear a dial
tone, call your security dealer for service. If you don't hear dial from any phones, telephone service in
your area may be out.
Phone Failure Trouble takes precedence over other system problems, so you must clear the Phone
Failure message (by disarming the panel) before you're able to see other system messages.
There is a receiver failure or receiver interference problem. Call your security dealer for service.
There is a system memory failure. Call your security dealer for service.
It contains specific information about the setup of your system. The User Sheets should be com-
pleted by the installer and the user.

Account Number

My central station account number is:
______________________________________________

System Sensors

Record the sensor number and name in the table below. Indicate whether it is a:
hardwired sensor (HW),
wireless sensor (WL),
or touchpad (TP).
No.
Sensor Name
01
02
03
04
05
06
HW / WL / TP
Security Pro 500

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

60-80660-806-95rSecurity pro 60-806

Table of Contents