16.5 SEPARATE VERTICAL FLUE INSTALLATION OPTIONS
This machine is only electrically safe if it is correctly connected to an efficient earth system in compliance with current safety regula-
tions.
Connect the boiler to a 230V single-phase earthed power supply using the supplied three-pin cable, observing correct LIVE-NEUTRAL
polarity.
Use a double-pole switch with a contact separation of at least 3 mm.
When replacing the power supply cable, fit a harmonised HAR H05 VV-F' 3x0.75mm2 cable with a maximum diameter of 8 mm.
...Access to the power supply terminal block
•
disconnect the boiler from the mains power supply using the two-pole switch;
•
remove the two screws fixing the control panel to the boiler;
•
rotate the control panel;
•
remove the cover and access the wiring area (figure 11).
The 2A fast-blowing fuse is incorporated in the power supply terminal block (to check and/or replace the fuse, pull out the black fuse car-
rier).
(L) = Live (brown)
(N) = Neutral (blue)
= Earth (yellow-green)
(1) (2) = Contact for ambient thermostat
IMPORTANT
: respect polarity L (LIVE) - N (NEUTRAL)
Figure 11
WARNING:
If the appliance is directly connected to an underfloor system, install a safety thermostat to prevent the latter from
overheating.