Electrical safety of the appliance is only guaranteed by correct grounding, in compliance with the applicable laws and
regulations.
Connect the boiler to a 230V monophase + ground power supply by means of the three-pin cable supplied with it and make
sure you connect polarities correctly.
Use a double-pole switch with a contact separation of at least 3mm in both poles.
In case you replace the power supply cable fi t a HAR H05 VV-F' 3x0.75mm
...Access to the power supply terminal block
• isolate the electrical supply to the boiler by the double-pole switch;
• unscrew the two screws securing the control board to the boiler;
• rotate the control board;
• unscrew the lid and gain access to the wiring (Figure 10).
The 2A fast-blowing fuses are incorporated in the power supply terminal block (to check or replace the fuse, pull out the
black fuse carrier).
IMPORTANT : be sure to connect polarities correctly L (LIVE) - N (NEUTRAL).
(L) = Live (brown)
(N) = Neutral (blue)
(
) = Ground (yellow/green)
(1) (2) = Room thermostat terminal
CAUTION: If the appliance is directly connected to a underfl oor system, the fi tter must install a safety thermostat
to prevent it from overheating.
925.492.2
BAXI - 925.200.1

16. CONNECTING THE MAINS SUPPLY

Figure 10
2
cable with an 8mm diameter max.