Connecting The Mains Supply; Installing The Rfiu01 Base - Baxi LUNA 3 COMFORT AIR Series Installers And Users Instructions

High efficiency wall-mounted gas-fired boilers
Hide thumbs Also See for LUNA 3 COMFORT AIR Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 39

16. connecting the mains supply

Electrical safety of the appliance is only guaranteed by correct grounding, in compliance with the applicable laws and
regulations.
Connect the boiler to a 230V monophase + ground power supply by means of the three-pin cable supplied with it and
make sure you connect polarities correctly.
use a double-pole switch with a contact separation of at least 3mm in both poles.
In case you replace the power supply cable fit a HAr H05 VV-F' 3x0.75mm
...access to the power supply terminal block
• isolate the electrical supply to the boiler by the double-pole switch;
• unscrew the two screws securing the control board to the boiler;
• rotate the control board;
• unscrew the lid and gain access to the wiring (Figure 10).
The 2A fast-blowing fuses are in cor po rated in the power supply terminal block (to check or replace the fuses, pull out the
black fuse carrier).
iMportant: be sure to connect polarities cor-
rectly l (LIVE) - n (NEuTrAL).
(L) = live (brown)
(N) = neutral (blue)
= Ground (yellow/green)
(1) (2) = room thermostat terminal
wArNING: If the heating is directly connected
to a floor heating system, a safety overheating
thermostat should be provided by the instal-
ler.
The LuNA3 COMFOrT AIr boiler is controlled by a radiofrequency (wireless) remote control / climate controller. The
system comprises two separate units:
• The climate controller, known as rFrc01, is the boiler control unit which is used to set parameters, temperatures,
operating states and view information and fault messages;
• The base, known as rFiu01, acts as an interface between the climate controller and the electronic card of the boi-
ler.
• Connect the wires from boiler terminal block M2 (Fig. 12) as illustrated in figure C.
Figure a
WarninG: the base is powered at LOW VOLTAGE. Do not connect it to the 230 V mains supply. For electrical connec-
tions, see sections 26 and 31.
inStructionS Pertaining to the inStaller
Figure 10

17. installing the rfiu01 base

Figure B
cable with an 8mm diameter max.
2
Figure c
58
- GB
926.427.1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Luna 3 comfort air 310 fiLuna 3 comfort air 250 fi

Table of Contents