NB: For the C52 type, do not fit the flue and air duct terminals on opposite walls of the building. The air duct (for horizontal discharges)
must have a maximum length of 10 metres (6m for model 140 Fi).
If the discharge duct is longer than 6 metres, install the condensate collection kit, supplied as an accessory, near the boiler.
IMPORTANT:
if fitting a single flue duct, make sure it is adequately insulated (e.g.: with glass wool) wherever the duct passes
through building walls. For detailed installation instructions, consult the technical data provided with the accessories.
16.4 SEPARATE HORIZONTAL FLUE TERMINALS INSTALLATION OPTIONS
IMPORTANT -
Make sure there is a minimum downward slope towards the outside of 1 cm per metre of duct length. If the con-
densate collection kit is installed, the discharge duct must slope down towards the boiler.
INSTRUCTIONS FOR FITTERS
MAX LENGTH
AIR REGULATOR
L1+L2 (m)
0 ÷ 10
10 ÷ 20
20 ÷ 30
0 ÷ 20
20 ÷ 30
0 ÷ 20
20 ÷ 30
0 ÷ 10
10 ÷ 25
(L1 + L2) max = 30 m
(L1 + L2) max = 25 m for model 320 Fi
19
POSITION OF
AFR
G20
1
2
4,0
3
1
6,1
2
1
7,1
2
3
6,7
4
L max = 10 m
CO2%
G30
G31
4,3
8,7
8,7
8,0
8,0
7,6