Mode 5
You configure detailed settings of the read beginning
position and read line number. Set the read beginning
position in increments of 5 lines for the XCL-5005, and
in increments of 10 lines for the XCL-5005CR. Set the
read line number in increments of 1 line. Depending on
the camera module interface board (frame grabber
board) you are using, the pixels in the last line may not
display properly.
Use of this mode in combination with a partial scan
offset allows you to set the read beginning position and
read line number in increments of 1 line.
Read beginning
position PSAH
XCL-5005
Integer from 0 to 408
XCL-
Even number from 0 to
5005CR
408
The line number A of the actual video, vertical blanking
period B, and frame rate are determined by the values of
the read line number PSAF and partial scan offset.
A [LINE]
PSAF
*
B [LINE]
PER
– PSAF
Rate [fps]
1000000/(PER × 31.5)
* PER = 432 + 0.8 × (PSAF + PARTIAL-OFFSET)
Set the PARTIAL-OFFSET and read line number PSAF
so that the total line number does not exceed the actual
video range that can be output.
PARTIAL-OFFSET + PSAF ≤ 2050
20
4. Camera mode
Read line number
PSAF
1 to 2050
1 to 2050