Power Supply Status; Cr4S-8 Blade Led Descriptions - IBM SAN384B Installation, Service And User Manual

System storage
Table of Contents

Advertisement

Power supply status

To determine the status of a power supply:
1. Check the LED indicator on the power supply (see Figure 28 on page 57). The
2. Check the power supply status by entering psShow.
56
SAN384B Installation, Service, and User Guide
Table 11. CR4S-8 blade LED descriptions
LED purpose
Color
Power
Steady green
No light (LED is off)
Status
No light (LED is off)
Steady amber
Slow-flashing amber
(on 2 seconds; then
off 2 seconds)
Fast-flashing amber
(on 1/2 second; then
off 1/2 second)
LINK LED
No light (LED is off)
Steady green
ATTN LED
No light (LED is off)
Blinking amber
LED patterns may temporarily change during POST and other diagnostic tests;
for information about how to interpret the LED patterns, see Table 12 on page
57.
The power supply status displays OK, Absent, or Faulty. If a power supply is
absent or faulty, contact IBM.
Recommended
Status
Action
CR4S-8 blade is on.
No action required.
CR4S-8 blade is not
Ensure blade is
on.
firmly seated and has
power.
CR4S-8 is either
Verify that the power
healthy or does not
LED is on.
have power.
CR4S-8 blade is
Ensure that the blade
faulty or the switch
is firmly seated and
is still booting.
the switch has
completed booting. If
the LED remains
amber, contact IBM..
CR4S-8 blade is not
Pull the blade out
seated correctly or is
and reset it. If the
faulty.
LED continues to
flash, replace the
blade.
Environmental range
Check for
exceeded.
out-of-bounds
environmental
condition and correct
it.
No ICL or ICL cable
Ensure that the ICL
present, but no
cable is correctly
connection.
installed.
ICL connected
No action required.
ICL is operational
No action required.
Attention required
Ensure that the ICL
cable is correctly
installed.