Overview Of Installation Steps; Installing The Remote On/Off Switch - Xantrex XPower Inverter 3000 Installation Manual

Xpower inverter 3000
Hide thumbs Also See for XPower Inverter 3000:
Table of Contents

Advertisement

Overview of Installation Steps

Installing the Remote On/Off Switch

975-0556-01-01
Copper chassis ground cable, as selected in
on page
1–8, with 5/16" size ring terminal for connection to ground
stud.
AC output cable (if using the hardwire terminals)
Battery isolator (if connecting to a multiple-battery system)
Two provided DC terminal covers
Battery selector switch
Alternator controller
High-output alternator
These are the five steps for installing your inverter. Do not proceed with
installation until you have read
page
2–2.
1. Install the Remote On/Off Switch.
2. Mount the inverter.
3. Connect the chassis ground.
4. Connect AC output (if connecting to an existing AC circuit).
5. Connect the DC cables.
The Remote On/Off switch can be plugged into the remote switch jack on
the front of the inverter. The remote switch lets you turn the inverter on
and off from a convenient location—up to 20 feet (6 m) away from the
inverter.
Optional equipment only. Use as needed by your specific installa-
1.
tion.
This guide for use by qualified installers only.
1
1
1
"Installing the Inverter"
Installing the Inverter
"Selecting Cable Sizes"
starting on
2–3