Problem
The vacuum cleaner suddenly stops
Dust leaks from the vacuum cleaner
Electrostatic current on the vacuum
cleaner
GB
C385

Troubleshooting

Cause
Clogged primary filter
Clogged vacuum hose
Insufficient airflow
The filter is torn
Inadequate filter
Non existent or inefficient grounding
12
Remedy
Shake the filter.
Replace it if necessary
Check and clean the air intake
Increase air supply pressure. Check the pressure
supplied by the pneumatic network is sufficient.
Replace it with another of identical type.
Replace it with another of a suitable category and
check.
Check the ground.
The vacuum hose must be conductive.