8 Troubleshooting

Fault
‡ Motor does not start
‡ Motor does not run in
automatic mode
‡ Reduced suction power
‡ No suction power during
wet cleaning
(ATTIX 961-01)
‡ Voltage fluctuations
24
> Fuse of the mains socket has
blown.
> Overload protection switch
has tripped.
> Motor is faulty.
> Power tool/pneumatic tool is
1)
defective or not connected
properly.
> The power rating of the
electrical tool is too low.
> Suction power selected with
suction power control is too
low.
> Clogged suction hose/nozzle.
> Tank, disposal bag or filter
bag is full.
> Filter element is clogged.
> Seal between tank and upper
section of vacuum cleaner is
faulty or missing.
> Cleaning mechanism is
defective.
> Tank is full.
> Impedance of power supply is
too high.
Cause
• Connect mains fuse.
• Switch off the vacuum cleaner
• Have motor changed by Nilfisk
• Check that the power tool
• Note that minimum power
• Set suction power in
• Clean suction hose/nozzle
• See "Emptying tank" or
• See section „Cleaning filter
• Replace seal.
• Contact Nilfisk Service.
• Switch off the cleaner. Empty
1)
Optional accessories / Option depending on model
Remedy
and allow it to cool for approx.
5 minutes. If the cleaner
cannot be started again,
contact the Nilfisk service
department.
Service.
works or that the plug is
inserted correctly.
rating is P>40W
accordance with section
„Setting suction power".
"Replacing disposal bag, filter
bag" sections.
element" and „Replacing filter
element".
the tank.
Connect the cleaner to another
socket closer to the fuse box.
Voltage
fluctuations
7% should not occur if the
impedance at the transfer point
is 0.15 .