TANDBERG C20 Administrator's Manual page 64

Tandberg quick set c20/c20plus
Hide thumbs Also See for C20:
Table of Contents

Advertisement

Quick Set C20/C20plus
Contents
Introduction
Contents
Introduction
Other formats supported (configurable through
Dip-switch):
1920x1080@60fps (HDMI only)
1920x1080@50fps (HDMI only)
1920x1080@30fps
1920x1080@25fps
1280x720@60fps
1280x720@50fps
1280x720@30fps
1280x720@25fps
Automatic or manual focus/brightness/white
balance
Far-end camera control
Dual HDMI and HD-SDI output
Upside-down mounting with automatic flipping
of picture
PRECISIONHD 1080P 4X CAMERA
1/3" CMOS
4 x zoom
+15°/-25° tilt, +/- 90° pan
43.5° vertical field of view
72° horizontal field of view
Focus distance 0.3m–infinity
1920 x 1080 pixels progressive @ 30fps
Other formats supported (configurable through
Dip-switch):
1920x1080@30fps
1920x1080@25fps
1280x720@30fps
1280x720@25fps
Automatic or manual focus/brightness/white
balance
Far-end camera control
Dual HDMI and HD-SDI output
Upside-down mounting with automatic flipping
of picture
SYSTEM MANAGEMENT
Support for the TANDBERG Management Suite
Total management via embedded SNMP,
Telnet, SSH, XML, SOAP
Remote software upload: via web server, SCP,
D14489.01—JULY 2009
Getting started
About the menus
Getting started
About the menus
HTTP, HTTPS
Remote control and on-screen menu system
DIRECTORY SERVICES
Support for Local directories (My Contacts)
Corporate Directory
Unlimited entries using Server directory
supporting LDAP and H.350
Unlimited number for Corporate directory
(through TMS)
200 number local directory
Received Calls
Placed Calls
Missed Calls with Date and Time
POWER
Auto-sensing power supply
100–240 VAC, 50/60 Hz
45 watts max. for codec and main camera
OPERATING TEMPERATURE AND HUMIDITY
0° C to 35° C (32° F to 95° F) ambient
temperature
10% to 90% Relative Humidity (RH)
STORAGE AND TRANSPORT TEMPERATURE
-20° C to 60° C (-4° F to 140° F) at RH 10–90%
(non-condensing)
* requires Premium Resolution option
** requires Premium Resolution option and Quick Set C20plus
Advanced settings
Settings library
Advanced settings
Settings Library
APPROVALS
Directive 2006/95/EC (Low-Voltage Directive)
— Standard EN 60950-1
Directive 2004/108/EC (EMC Directive) —
Standard EN 55022, Class B — Standard EN
55024 — Standard EN 61000-3-2/-3-3
Approved according to UL 60950-1 and CAN/
CSA-C22.2 No. 60950-1-07
Complies with FCC15B Class A
DIMENSIONS OF CODEC C20
Length: 15.35"/39.0cm
Height: 1.18"/3.0cm
Depth: 5.0"/12.7cm
Weight: 4.0lbs/1.8kg
Administrator Guide
Cameras
Appendices
Cameras
Appendices
Appendices
All specifications subject to change without notice,
system specifics may vary.
All images in these materials are for representational
purposes only, actual products may differ.
TANDBERG and Expressway are registered
trademarks or trademarks of TANDBERG in the U.S.
and other countries.
All other trademarks are property of their respective
owners.
MTBF PRODUCT RELIABILITY/MTBF
The predicted reliability is expressed in the expected
random Mean Time Between Failures (MTBF) for the
electronic components based on the Power On Hours:
Power On Hours (POH) > 69 000 hours
Useful Life Cycle > 6 years
ISO 9001 certificate is available upon request
July 2009