Carrier VECTOR 6500 Operation & Service Manual page 130

Single-temp trailer and rail refrigeration units with advancet microprocessor
Table of Contents

Advertisement

Message
MICRO WILL STOP IN XXX SECONDS
MIN SETPOINT HAS BEEN REACHED
MODIFIED
NEW SW: = TO LOAD, TO ↑ CANCEL
NO ACTION TAKEN, REMOVE CARD
NO ACTIVE ALARMS
NO DATA ON CARD, REMOVE CARD
NO DATA TO COPY, REMOVE CARD
NO INACTIVE ALARMS
NO INSTALLS LEFT, REMOVE CARD
OLD INTELLISETS-USE REEFERMAN
OLD SW:CANNOT LOAD-REMOVE CARD A Program PC Card has been inserted into the PC Card slot, and
OLD SW, = TO LOAD, ↑ TO CANCEL
PC MODE
PM DUE
PRESS ↑↓ TO VIEW DATA
PRESS ↑↓ TO VIEW SETTINGS
PRESS ↑↓ TO VIEW PRINT MENU
PRESS = TO MARK TRIP START
PRESS = TO START PRETRIP
PRESS ↑↓ TO VIEW INTELLISET
62-11389
MessageCenter MESSAGES - Continued
The Main Power switch has been placed in the OFF position and
the system valves are closing. The display will turn off when the
count down reaches zero.
Minimum Set Point allowed by configuration settings has been
reached.
This message will appear in the MessageCenter along with the cur-
rent IntelliSet indicating that the IntelliSet is active and one or more
of its settings have been modified.
A Program PC Card has been inserted into the PC Card slot, and
the program on the PC Card is a newer version than what is al-
ready loaded in the microprocessor. Press the = key to load the
program.
A Program PC Card has been inserted into the PC Card slot, and
no key presses have been made to install the program into the mi-
croprocessor. The PC Card may be safely removed from the slot.
There are no active alarms in the microprocessor Alarm List.
A Program or Configuration PC Card has been inserted into the PC
Card slot, and no valid data is present on the PC Card. The PC
Card may safely be removed from the unit.
A Download PC Card has been inserted into the PC Card slot, and
there is no valid data in the DataLink data recorder to copy onto the
PC Card. The PC Card may safely be removed from the unit.
There are no inactive alarms in the Alarm List
An Option PC Card has been inserted into the PC Card slot, and all
install options have been used. The PC Card may safely be re-
moved from the unit.
The IntelliSets that are on the Configuration PC Card were written
with too old of a PC Program, like ServiceManager. The software in
the micro requires IntelliSets to be written to the Configuration PC
Card using ReeferManager. Rewrite the information to the card us-
ing ReeferManager, then use it in the microprocessor again
the major version of the program on the PC Card is an older vers-
ion than what is already loaded in the microprocessor. Software
with older major versions can not be loaded into the micropro-
cessor. Remove the PC Card.
A Program PC Card has been inserted into the PC Card slot, and
the minor version of the program on the PC Card is an older ver-
sion than what is already loaded in the microprocessor. Press the =
key to load the older program.
The Main Power switch is in the OFF position, the PC Mode Jump-
er is connected and engine is not running in order to enter PC
Mode.
Preventative Maintenance is now due on the unit.
Press the UP or DOWN ARROW key to scroll through the Data
List.
Press the UP or DOWN arrow key to scroll through Functional Pa-
rameter Settings.
Press the UP or DOWN arrow key to view the Strip Print setup
menu.
Press the = key to mark the start of the trip in the DataLink data
recorder.
Press the = key to begin Pretrip tests.
Press the UP or DOWN arrow key to view IntelliSet list. This mes-
sage will appear after IntelliSets are installed into the micropro-
cessor, and the unit can not be started until an IntelliSet is selec-
ted.
Description
6−4