4.0

CONFIGURING THE CAN-6

The CAN-6 receiver will be pre-configured at the factory in most cases; the following
sections are for reference for field adjustments.
NOTE: Changing settings must be done with caution. Wrong settings can cause the
equipment not to function and potentially cause damage to equipment or injury.
4.1

SETTING ANTENNA TYPE

The antenna can be selected from internal to external on the CAN-6 module by utilizing
SW8 on the Bank 1 dip switches.
Antenna Type
Internal
External
NOTE: If the CAN-6 module is installed inside an enclosure, an external antenna must be
used and the antenna type dip switch setting should be set to External.
NOTE: See Section 3.4 for instructions on how to remove the CAN-6 module from the
module housing.
4.2

REMAINING BANK 1 DIP SWITCH SETTINGS

The Bank 1 dip switches 1 through 7 are programmed at the factory for custom setting
adjustments. Examples of settings that can be utilized are A, B, Both, RF Power, CAN
Message Types, etc.
SW8
Up
Down
Enrange CAN-6 Instruction Manual