CONVERSION KIT INSTRUCTIONS
FLAME APPEARANCE:
Flame appearance is affected by several factors including altitude, venting configuration and fuel quality. Although the venturi setting has
been factory set, adjustments may be necessary for optimal performance and visual aesthetics.
When fireplace is first lit, the flames will be blue. Flames will gradually turn yellowish-orange during first 15 minutes of operation. If
flames remain blue, or become dark orange with evidence of sooting (black tips), the burner tube venturi may need adjustment.
Correct pilot flame
Figure 18a
WARNING
Burner tube adjustable venturi positioning should only be performed by a qualified professional service technician.
NATURAL GAS
1/16" (2mm) OPEN
VENTURI POSITION
Closed too far
Open too far
SL I G HT AD J U STM EN T S T O BU R N ER VE N TU RI OP EN IN G CR E A TE D R AM A TI C R E SU LT S. A D J U ST AT SL I G HT
IMPORTANT
INCREM ENT S UNTIL DESI RED LOOK IS ACHI EVED. AL WAY S BURN FIREPLAC E FOR AT LEAST 15 M INUTES
AND ALLOW TIME TO COOL BEFORE MAKING ANY FURTHER ADJUSTMENTS.
TO ADJUST VENTURI:
1.
Remove screen front and glass frame assembly.
2.
Remove glass media.
3.
Remove burner assembly.
4.
Loosen screw on burner venturi and adjust as necessary. Tighten screws.
5.
Reinstall all components previously removed.
6.
Light fireplace and wait 15 minutes before determining if any further adjustments are
needed.
Figure 18b
FACTORY SET BURNER TUBE VENTURI SETTINGS
(ADJUST AS NECESSARY FOR YOUR INSTALLATION)
BURNER TUBE VENTURI ADJUSTMENT GUIDELINES
FLAME COLOR
Dark orange flame with black tips
Blue flames
Lazy yellow flames - ideal
Dark orange flames / black tips
Venturi closed too far
Excessive burner media
LP (PROPANE) GAS
5/8" (16mm) OPEN
Open venturi setting slightly
Close venturi setting slightly
18
Short blue flames
venturi open too far
Lifting (ghosting) flames
Improper Venting
Gas pressure too high
VENTURI ADJUSTMENT
BURNER VENTURI
Figure 18c