MAINTENANCE (cont'd)
6. Make sure the bumper skirt is in position. The
bumper skirt prevents solution from flowing from
under the frame.
7. Make sure the brush is in position.
8. Make sure the vacuum hose is installed and on
the squeegee. See Figure #19.
9. Connect the power cord to the electrical outlet.
Procedures to be Performed at the End of
Work
1. Disconnect form power.
2. Drain and flush the tanks. To drain the recovery
and solution tanks, follow this procedure:
1. Remove the drain hose from the fitting on the
back of the machine.
2. Put the end of the hose over a drain or
bucket.
3. Run clean water into the solution and
recovery tanks to flush the tanks.
4. Put the end of both hoses over a drain or
bucket.
3. Leave the tanks and the drain hoses open to dry
in the air.
4. Check and clean the squeegee blade. Use a
soft cloth to clean the squeegee blade. If the
squeegee blade is damaged or worn, turn or
replace the blade.
5. Check and clean the vacuum gaskets, the vac
screen filter and the solution screen filter. Re-
move and clean with a vinegar-water solution or
warm soapy water. Rinse the parts in clean
water.
6. Use a clean cloth and wipe the surface of the
machine.
7. Remove the brush or pad driver. Rinse clean
and allow to dry. Discard the pad if necessary.
8. Store the machine and accessories in a dry
building.
Page -16-
Figure #18
Figure #19
CLARKE TECHNOLOGY Operator's Manual -Vision 17E 115V