US Robotics COURIER User Manual page 161

Courier high speed modems
Table of Contents

Advertisement

COURIER HIGH SPEED MODEMS
5.
If password security is not active (no passwords have been
set or both passwords are disabled), the Courier automati-
cally enters Remote Access mode and the remote prompt
appears on the caller's screen.
Remote->
6.
Once the remote access session has been established, keep in
mind that there is a 3-minute inactivity timer. If the modem
detects no activity for 3 minutes, it aborts the remote access
session and resumes a normal online connection.
Aborting the Request for Remote Access
You can abort the remote access login procedure and return
online by pressing the key combination <Ctrl>-C.
Remote Viewing and Configuration
Once you've gained remote access, you can communicate with
the Courier as if you were typing commands at its attached ter-
minal or computer. Depending on your access privileges, you
can use the regular Courier AT commands.
If
you have view privileges only (with Password
0),
you can use
any of the view commands described in Chapter 8.
If you have view and configure privileges (with Password
1),
you can use any of the Courier commands, except those com-
mands that cannot be used while online, such as the Dial com-
mand. You can also use the remote access commands described
later.
When you make remote configuration changes, the remote
prompt is altered to indicate that changes have been made. The
prompt will change from:
Remote->
to
Remote+>
If you restore the original configuration (with %Cl, explained
next), the original prompt is also restored (back to Remote->),
indicating that the original configuration is intact.