3.05 Domina top outlet flue conversion
Remove fan by pulling off electrical connections. Pull off air pressure switch tubes from the air pressure
switch remove 2 screws b. Rotate the fan upward to disengage it from the securing pin a.
1
2
Remove the securing screw that locates the fan nozzle extension to the fan and remove the nozzle
extension and jointing mastic (this is not required for top outlet flueing).
DOMINA 80 E
b
b
2
Rear
Fig. 17a
1
Rear
a
Fig. 17b