Ferroli DOMIcompact F 30 D Instructions For Use, Installation And Maintenance

Ferroli DOMIcompact F 30 D Instructions For Use, Installation And Maintenance

Wall-mounted gas fired, combination boiler
Hide thumbs Also See for DOMIcompact F 30 D:
  • (34 pages)

Advertisement

DOMIcompact F 30 D
wall-mounted gas fired,
combination boiler
INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE
FOR THE UNITED KINGDOM & EIRE
GC N° 47-267-40

Advertisement

Table of Contents
loading

Summary of Contents for Ferroli DOMIcompact F 30 D

  • Page 1 DOMIcompact F 30 D wall-mounted gas fired, combination boiler INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE FOR THE UNITED KINGDOM & EIRE GC N° 47-267-40...
  • Page 2 “This record must be completed and left with the end user”. Ferroli is a member of the Benchmark initiative and fully supports the aims of the programme. Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency.
  • Page 3: Table Of Contents

    DOMIcompact F 30 D 1. Operating instructions ................4 1.1 Introduction ......................4 1.2 Control panel ......................5 1.3 Turning on and off ....................6 1.4 Adjustments ......................6 1.5 Maintenance ......................8 1.6 Faults ........................8 2. Installation ....................9 2.1 General Instructions ....................9 2.2 Boiler location .......................10 2.3 Boiler water connections ..................12...
  • Page 4: Operating Instructions

    Please read this manual carefully and keep it for future reference. DOMIcompact F 30 D is a high-efficiency non condensing appliance for heating and hot water production running on natural or liquefied petroleum gas (configurable at the time of installation) and regulated by an advanced microprocessor control system.
  • Page 5: Control Panel

    DOMIcompact F 30 D 1.2 Control panel The control panel is composed of a multi-function button, two knobs and a display. 1 Heating temperature adjustment and Summer/Winter/ switch off control 2 Hot water temperature adjustment and switch off control 3 Multi-function button (ECO/RESET/TEST)
  • Page 6: Turning On And Off

    DOMIcompact F 30 D 1.3 Turning on and off Ignition • Open the gas isolation valve on the boiler. • Purge the air from the pipe work to the gas valve. • Turn on the 3amp electrical switch or insert the plug to the boiler.
  • Page 7 DOMIcompact F 30 D Switching off the boiler. Switching between summer and winter operation has priority over the heating only time control (optional) when this is connected to the boiler. C.H. temperature setting To set the system delivery temperature, turn the knob (ref. 1 - Fig. 1).
  • Page 8: Maintenance

    If the problem remains after two attempts at resetting, contact the Ferroli Service Centre. For other faults, refer to section 3.4 “Troubleshooting”. Before calling a Ferroli service engineer, check that the problem is not due to there being no gas or electricity, or low system pressure.
  • Page 9: Installation

    DOMIcompact F 30 D 2. INSTALLATION 2.1 General Instructions This device must only be used for the purpose for which it is specially designed. This unit is designed to heat water to a temperature below boiling point and must be connected to a hea- ting system and/or a water supply system for domestic use, compatible with its performance, characteristics and its heating capacity.
  • Page 10: Boiler Location

    DOMIcompact F 30 D 2.2 Boiler location The boilers combustion chamber is sealed off from the installation room. The installation room must be sufficiently well ventilated to prevent any dangerous conditions from forming in the event of even slight gas leakage. This safety standard is required by the EEC Directive no. 90/396 for all gas units, including those with a so-called sealed chamber.
  • Page 11 DOMIcompact F 30 D Make Up Water Provision must be made for replacing water lost from the sealed system. Reference should be made to BS6798, for methods of filling and making up sealed systems. There must be no direct connection between the boiler's central heating system and the mains water supply.
  • Page 12: Boiler Water Connections

    DOMIcompact F 30 D 2.3 Boiler water connections The heating capacity of the unit should be previously established by calculating the building’s heat requirement according to current regulations. For efficient operation and long life of the boiler, the plumbing system must be well designed and always complete with all those accessories that guarantee regular operation and running, ie room thermostat, trv’s and automatic bypass etc .
  • Page 13: Water Treatment

    The connecting kits shown in fig. 7 are supplied as standard. fig. 7 Water treatment When treatment is used ferroli limited only recommend the use of proprietary Brand s , such as Fernox or Sentinel water treatment products, which must be used in accordance with the manufacturers instruc- tions, For further information contact: Fernox Manufacturing Co.
  • Page 14: Connection To The Gas System

    DOMIcompact F 30 D 2.4 Connection to the gas system If necessary the local Gas supplier should be consulted, at the installation planning stage, in order to establish the availability of an adequate supply of gas. An existing service pipe must not be used whitout prior consultation with the local Gas supplier.
  • Page 15 DOMIcompact F 30 D Integral clock installation 1 Unscrew the two screws “A” (Fig. 8a). 2 Lower the instrument panel (Fig. 8b). 3 Turn the instrument panel (Fig. 8c). 4 Open the instrument panel “B” (Fig. 8c), mount the clock into the facia panel using the two screws provided.
  • Page 16 DOMIcompact F 30 D Access to the electrical terminal block To access the terminal block where the room thermostat (Low voltage) or the remote timer control is to be connected, carry out the following operations: 1 Unscrew the two screws “A” (Fig. 9a).
  • Page 17: Flue System

    The current standards and local regulations must be observed. This C-type unit must be installed using the flue components supplied by FERROLI S.p.A. in accordance with UNI-CIG 7129/92. Failure to use them automatically forfeits all warranty and liability of FERROLI S.p.A.
  • Page 18 DOMIcompact F 30 D Connection with concentric flue The unit can be connected to a concentric flue with a horizontal or vertical flue as shown on the following drawings. Numerous accessories are available on request to meet the various installation requirements.
  • Page 19 DOMIcompact F 30 D The total length in linear metres of the flue Vertical Outlet pipe must not exceed the maximum lengths stated in the following table, considering that each bend gives rise to the stated reduction. For example, a duct D= 60/100 composed of 1 bend of 90°...
  • Page 20 DOMIcompact F 30 D Connection with two pipe system The unit can be connected to a system of separate air/flue ducts for a vertical or horizontal outlet as shown on the drawings 11 - 12 alongside. Numerous accessories are available on request to meet the various installation require- ments.
  • Page 21 DOMIcompact F 30 D Table of pipe and accessory losses Equivalent losses Equivalent losses in metres (linear) in metres (linear) Flue Flue Description Description Ø Ø The stated loss values refer to genuine Ferroli ducts and accessories.
  • Page 22 DOMIcompact F 30 D Terminal Position Fig. 13...
  • Page 23 If you are then going to connect the Domicompact F 30 D Boiler to a collective flue or a single flue with natural draught, the flue must be expressly designed by professionally qualified technical personnel in conformity with the UNI 10641 standard.
  • Page 24: Service And Maintenance

    All adjustment and conversion operations must be carried out by a Qualified and trained engineer such as a Ferroli Service engineer FERROLI S.p.A. declines any responsibility for damage or physical injury caused by unqualified and unauthorised persons tampering with the device.
  • Page 25 DOMIcompact F 30 D Adjusting burner pressure Since this unit has flame modulation, there are two fixed pressure settings: the minimum and maximum, which must be as stated in the technical data chart according to the type of gas. • Connect a suitable pressure gauge to pressure point “B” downstream from the gas valve, having loo- sened it first •...
  • Page 26: Initial Start-Up

    DOMIcompact F 30 D Adjusting the maximum heating output To adjust the heating power, set the boiler on TEST operation (see par. 3.1). Turn the heating tem- perature control knob (ref. 1 - Fig. 1) clockwise to increase the power or anticlockwise to decrease it (see pressure/power diagram Fig.
  • Page 27: Maintenance

    DOMIcompact F 30 D Checks during operation • Check the soundness of the gas circuit and water systems. • Check the efficiency of the flue and air-flue ducts while the boiler is working. • Check that the water is circulating properly between the boiler and the systems.
  • Page 28: Combustion Analysis

    DOMIcompact F 30 D Before carrying out any operation inside the boiler, disconnect the electrical power and isolate the gas supply. fig. 15a fig. 15b fig. 15c fig. 15d Cleaning the boiler and burner The body and burner must not be cleaned with chemical products or wire brushes. Special care must be taken over all the sealing systems pertaining to the sealed chamber (gaskets, cable clamps, etc.).
  • Page 29: Troubleshooting

    DOMIcompact F 30 D 3.4 Troubleshooting Fault Diagnosis The boiler is equipped with an advanced self-diagnosis system. In the event of a fault within the boiler, the display will show the relevant code. There are faults that cause shutdown (faults from F1 to F3): in order to restore operation it requires the operator to press RESET for 1 second (ref.
  • Page 30: Technical Characteristics And Data

    DOMIcompact F 30 D 4 TECHNICAL CHARACTERISTICS AND DATA Top view 4.1 Dimensions and connections Heating system flow Ø 3/4” Hot water outlet Ø 1/2” Gas inlet 1/2” Tap water inlet Ø 1/2” Heating system return Ø 3/4” Bottom view...
  • Page 31: General View And Main Components

    DOMIcompact F 30 D 4.2 General view and main components Airtight chamber Gas inlet Hot water outlet Cold water inlet System flow System return Safety valve Combustion chamber Burner assembly Injectors Burner Combustion chamber insulation Copper exchanger for heating and hot water...
  • Page 32: Hydraulic Diagram

    DOMIcompact F 30 D 4.3 Hydraulic diagram Fig. 19 Airtight chamber Heating pump Gas inlet Heating temperature sensor Tap water outlet Flow switch Tap water inlet Tap water temperature sensor System flow Air pressure switch System return Gas valve Safety valve...
  • Page 33: Technical Data Table

    DOMIcompact F 30 D 4.4 Technical data table êêê...
  • Page 34: Diagrams

    DOMIcompact F 30 D 4.5 Diagrams Burner pressure to boiler output Fig. 20 Circulator losses of head H [m H Q [l/h] 1.000 1.500 2.000 Fig. 21 = Circulator speed = Boiler losses of head...
  • Page 35: Time Clock (Optional)

    DOMIcompact F 30 D 4.6 Time Clock (optional) A 24 hour time clock can be optionally fitted to the boiler to control the central heating, this will come into operation when the selector switch “F“ is turned to the position marked “AUTO”.
  • Page 36: Wiring Diagram

    DOMIcompact F 30 D 4.7 Wiring diagram Fig. 22...
  • Page 37: Benchmark

    BENCHMARK 2 6 7 Please add the first 4 digits of the Boiler serial No to complete the BENCHMARK No. GAS BOILER COMMISSIONING CHECKLIST C O L L E C T I V E M A R K...
  • Page 38: Service Interval Record

    SERVICE INTERVAL RECORD Service Provider. SERVICE 1 SERVICE 2 SERVICE 4 SERVICE 3 SERVICE 5 SERVICE 6 SERVICE 7 SERVICE 8 SERVICE 9 SERVICE 10 FERROLI TECHNICAL HELPLINE - 08707 282 885 option 1...
  • Page 40 Should you require any assistance during the installation call our Technical Service Helpline on 08707 282 885 option 1 Should you require a service engineer to visit call our service centre on 08707 282 885 option 2 (For U.K. and Northern Ireland) For EIRE only call HEATOVENT on 014508166 Phone numbers:...