Controllers - Bathroom Deluxe installation

1. Determine the most suitable position for the controller.
2. Mark and drill three holes, locating the cable access hole as shown (Fig.1).
3. When running a cable through the access hole ensure the connector end of the cable is
located nearest to the controller (Fig.2).
4. Affix the double sided self-adhesive seal to the back of the controller (Fig.3).
5. Carefully remove the face plate from the controller. Do this by placing your thumbs on the
front digital display while hooking your fingers behind the top plate and gently push down
as shown (Fig.4). Do not use a screwdriver as this may damage the controller.
6. Connect the cable to the bathroom controller. Feed excess cable lengths into the wall cavity
to avoid pinching of cables between the wall and the controller.
7. Fix bathroom controller to the wall using appropriate fixings. Avoid the use of impact drills
and over-tightening of fixings as this may damage the controller.
8. Remove the protective plastic from the controller face and replace the face plate.
Outline of Water Controller
181
Ø20 Cable Access
195
Fig.1
Fig.3
Rinnai New Zealand Ltd.
Securing
Screw
Backing Seal
Remove
to expose
self-adhesive
Controller Cable
Fig.2
Fig.4
Continuous Flow Water Heater Installation Manual:
18
Connector
03-11