Connections and fittings

Models
Gas Consumption
VT16 Ext
REU-VR1620WG
VT20 Ext
REU-VR2024WG
VT24 Ext
REU-VR2426WG
VT26 Ext
REU-VR2626WG
VTa26
REU-VR2626WGT
HD200 Ext
REU-VRM2632WC
HDi200 Int
REU-VR2632FFUG
HD250 Ext
REU-VR3237WG
EF24 Ext
REU-K2430WG
EF250 Ext
REU-KM3237WD
EFi250 Int
REU-KM3237FFUD
Service connection points
These dimensions are NOT an indication of the pipe sizes required.
An approved full flow isolation valve and disconnection union MUST be fitted to the cold water
inlet. A non-return valve is not required unless required by local regulations.
Isolation valves must be fitted so the appliance can be removed.
Purge gas and cold water supply lines to remove air and swarf before final connection of the
appliance. Swarf in the gas or water supplies may cause damage.
Rinnai New Zealand Ltd.
Water
MJ/h
Supply kPa
Min.
Max.
125
120
1000
160
160
1000
188
180
1000
199
180
1000
199
180
1000
199
140
1000
195
140
1000
250
200
1000
162
240
1000
211
240
1000
211
240
1000
Weight
Fittings
kg
Hot
15
(15 mm)
(15 mm)
16
(20 mm)
(20 mm)
17
(20 mm)
(20 mm)
17
(20 mm)
(20 mm)
17
(20 mm)
(20 mm)
21
(20 mm)
(20 mm)
21
(20 mm)
(20 mm)
29
(20 mm)
(20 mm)
27
(20 mm)
(20 mm)
32
(20 mm)
(20 mm)
32
(20 mm)
(20 mm)
Continuous Flow Water Heater Installation Manual:
8
Condensate
Cold
Gas
(20 mm)
(20 mm)
(20 mm)
(20 mm)
(20 mm)
(20 mm)
(20 mm)
(20 mm)
(20 mm)
(15 mm)
(20 mm)
(15 mm)
(20 mm)
(15 mm)
03-11