Dip switch settings

Applicable models and REU-numbers
Rinnai Infinity VT16
Rinnai Infinity VT20
Rinnai Infinity VT24
Rinnai Infinity VT26
Rinnai Infinity VTa26
Rinnai Infinity EF24
Dip Switch 1: Upper SW(8P)
SW No.
Note
1
Fixed temperature
2
(with controllers)
3
4
Temperature settings
5
6
7
Gas pressure
8
Chart A: Temperature Settings
Dip.SW.1-SW No.(8P)
3
4
5
Off
Off
Off
On
Off
Off
Off
On
Off
On
On
Off
Off
Off
On
On
Off
On
Off
On
On
On
On
On
Dip Switch 2: Lower SW(4P)
SW No.
Note
1
Gas type
2,3,4
Model settings
Chart B: Model Settings
Dip.SW.2-SW No.(4P)
2
3
4
Off
Off
Off
Off
On
Off
Off
Off
On
Off
On
On
Rinnai New Zealand Ltd.
External
REU-VR1620WG
External
REU-VR2024WG
External
REU-VR2426WG
External
REU-VR2626WG
External
REU-VR2626WGT
External
REU-K2430WG
Off
Off
Fixed temperature
See Chart A
Off
Off
On
Normal
Off
Off
SW No.2 = Off
(fixed temperature)
No controllers
(fixed temp.)
55
75
65
60
50
42
not to be used
not to be used
Off
LPG
On
See Chart B
Model (REU-number)
VT26 (VR2626WG), VTa26 (VR2626WGT) and EF24 (K2430WG)
VT24 (VR2426WG)
VT20 (VR2024WG)
VT16 (VR1620WG)
On With controllers
On
Forced min.
On
SW No.2 = On
(with controllers)
No controllers
With controllers
(fixed temp.)
(max. set temp.)
55
55
55
75
55
65
55
60
50
50
42
42
40
40
55
75
NG
Continuous Flow Water Heater Installation Manual:
24
Off
On
Forced max.